Instance Attributes
Services
Parameter Object
(Class ID 0F
H
)
The Parameter Object provides the interface to the XM-123 configuration
data. There are 32 Parameter Object instances implemented in the XM-123
module.
Instances 1-28 are implemented to provide an alternate method of setting the
configuration parameters with EPATH or ENGUNIT data types. And
Parameter Object instances 31 and 32 provide an alternate method of setting
the Produced Connection Size and Produced Connection Path attributes for
the Poll Connection because these attributes can be difficult to get/set directly
through the Connection Object.
Parameter Object instances 29 and 30 are for determining which filter
measurement (tracking or bandpass) is performed by the module.
Table C.19 Discrete Input Object Instance Attributes
Attr ID
Access
Rule Name Data Type Description Semantics
3 Get Value BOOL Setpoint Multiplier 0 = Off
1 = On
199 Set Backdoor
Service
USINT Setting this attribute is
equivalent to requesting
the specified service.
Set to one of the
following values to
perform the
specified service:
0x32 = Open
0x33 = Close
Table C.20 Discrete Input Object Services
Service
Code Class/Instance Usage Name Description
0E
h
Class/Instance Get_Attribute_Single Returns the contents of the
specified attribute.
10
h
Instance Set_Attribute_Single Sets the contents of the
specified attribute.
32
h
Instance Open Opens the virtual Setpoint
Multiplier switch.
33
h
Instance Close Closes the virtual Setpoint
Multiplier switch.
Vista de pagina 117