OC_InitScanner This function initializes the shared memory interface between the host and scanner
and this function configures the shared memory partitioning.
Syntax:
int OC_InitScanner(HANDLE handle, OCINIT *scaninit);
Parameters:
Description:
If the scanner is executing POST when this function is called, ERR_OCPOST is returned.
If the scanner has been previously initialized and the partition information in
scaninit is identical to the
current scanner partitioning, OC_InitScanner returns successfully.
If the scanner has been previously initialized and the partition information in
scaninit is different from
the current scanner partitioning, OC_InitScanner returns an error value that indicates that the scanner was
previously initialized. The scanner must be reset via OC_ResetScanner before the initialization information
can be changed. If the scanner has already been initialized, you can call OC_GetScannerInitInfo to retrieve
current partition information.
The
OCINIT structure is defined as:
typedef struct tagOCINIT
{
WORD OutputImageSize; /* size in bytes */
WORD InputImageSize; /* size in bytes */
WORD HostRetentiveDataSize; /* size in bytes */
} OCINIT;
Parameter: Description: