Publication 1756-IN019C-EN-P - November 2004Installation InstructionsControlLogix EtherNet/IP Bridge ModuleCatalog Number 1756-ENBTUse this document a
10 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Install the Module in the Chassis31275-M31276-MAlign the circ
ControlLogix EtherNet/IP Bridge Module 11Publication 1756-IN019C-EN-P - November 2004Remove or Replace the Module (when applicable)IMPORTANTIf you
12 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Install or Remove the Module Under PowerThis module is design
ControlLogix EtherNet/IP Bridge Module 13Publication 1756-IN019C-EN-P - November 2004Wire the Ethernet ConnectorUse an RJ45 connector to connect t
14 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Attach the RJ45 connector to the Ethernet port on the bottom
ControlLogix EtherNet/IP Bridge Module 15Publication 1756-IN019C-EN-P - November 2004Apply Chassis PowerCheck Power Supply and Module StatusCheck
16 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Troubleshoot the ModuleIf the alphanumeric display and LED in
ControlLogix EtherNet/IP Bridge Module 17Publication 1756-IN019C-EN-P - November 2004Link Status IndicatorThe Link Status LED provides the followi
18 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004SpecificationsModule Location Any slot in the ControlLogix ch
ControlLogix EtherNet/IP Bridge Module 19Publication 1756-IN019C-EN-P - November 2004Shock, Non-operatingIEC60068-2-27 (Test Ea, Unpackaged shock)
2 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004IImportant User InformationSolid state equipment has operation
Publication 1756-IN019C-EN-P - November 2004 PN 957944-26Supersedes Publication 1756-IN019B-EN-P - August 2001 Copyright © 2004 Rockwell Automation, I
ControlLogix EtherNet/IP Bridge Module 3Publication 1756-IN019C-EN-P - November 2004Environment and Enclosure Prevent Electrostatic DischargeATTEN
4 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Removal and Insertion Under PowerBe sure that power is removed
ControlLogix EtherNet/IP Bridge Module 5Publication 1756-IN019C-EN-P - November 2004North American Hazardous Location ApprovalThe following inform
6 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004WARNINGEXPLOSION HAZARD• Do not disconnect equipment unless po
ControlLogix EtherNet/IP Bridge Module 7Publication 1756-IN019C-EN-P - November 2004Identify Module ComponentsUse the following figure to identify
8 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Prepare the Chassis for Module InstallationBefore you install
ControlLogix EtherNet/IP Bridge Module 9Publication 1756-IN019C-EN-P - November 2004Determine Module Slot LocationYou can install the module in an