Rockwell-automation 1762-OX6I MicroLogix 1200 Relay Output Module Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1762-OX6I MicroLogix 1200 Relay Output Module. Rockwell Automation 1762-OX6I MicroLogix 1200 Relay Output Module User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Publication 1762-IN017C-EN-P - May 2013
Installation Instructions
MicroLogix 1200 Isolated Relay Output Module
Catalog Number 1762-OX6I
Table of Contents
Topic Page
Additional Resources 2
Description 3
Overview 3
Mounting 5
System Assembly 7
Field Wiring Connections 7
I/O Memory Mapping 10
Specifications 11
North American Hazardous Location Approval 15
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Installation Instructions

Publication 1762-IN017C-EN-P - May 2013Installation InstructionsMicroLogix 1200 Isolated Relay Output ModuleCatalog Number 1762-OX6ITable of ContentsT

Pagina 2 - Additional Resources

10 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013Wire Size and Terminal Screw TorqueEach terminal accepts up

Pagina 3 - Overview

MicroLogix 1200 Isolated Relay Output Module 11Publication 1762-IN017C-EN-P - May 2013SpecificationsGeneral SpecificationsSpecification ValueDimen

Pagina 4 - Remove Power

12 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013CertificationsCertification (when product is marked)(1)(1) S

Pagina 5 - Mounting

MicroLogix 1200 Isolated Relay Output Module 13Publication 1762-IN017C-EN-P - May 2013Relay Contact RatingsIsolated Groups Outputs 0 to 5: Individ

Pagina 6 - Panel Mounting

14 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013Module Load RatingsRelays Used vs. Maximum Current per Relay

Pagina 7 - Field Wiring Connections

MicroLogix 1200 Isolated Relay Output Module 15Publication 1762-IN017C-EN-P - May 2013North American Hazardous Location ApprovalThis equipment is

Pagina 8 - Labeling the Terminals

Publication 1762-IN017C-EN-P - May 2013Supersedes Publication 1762-IN017B-EN-P - March 2004 Copyright © 2013 Rockwell Automation, Inc. All rights rese

Pagina 9

2 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013Additional ResourcesIf you would like a manual, you can:• dow

Pagina 10 - O0:x.0/0

MicroLogix 1200 Isolated Relay Output Module 3Publication 1762-IN017C-EN-P - May 2013DescriptionOverview1762 I/O is suitable for use in an industr

Pagina 11 - Specifications

4 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013Prevent Electrostatic DischargeRemove PowerATTENTION!Electros

Pagina 12 - Output Specifications

MicroLogix 1200 Isolated Relay Output Module 5Publication 1762-IN017C-EN-P - May 2013MountingMinimum SpacingMaintain spacing from enclosure walls,

Pagina 13 - Relay Contact Ratings

6 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013Use DIN rail end anchors (Allen-Bradley part number 1492-EA35

Pagina 14 - Module Load Ratings

MicroLogix 1200 Isolated Relay Output Module 7Publication 1762-IN017C-EN-P - May 2013System AssemblyThe expansion I/O module is attached to the co

Pagina 15 - AVERTISSEMENT

8 MicroLogix 1200 Isolated Relay Output ModulePublication 1762-IN017C-EN-P - May 2013Output WiringBasic wiring(1) of the 1762-OX6I is shown below.

Pagina 16 - Rockwell Automation Support

MicroLogix 1200 Isolated Relay Output Module 9Publication 1762-IN017C-EN-P - May 2013Wiring the Finger-Safe Terminal BlockWhen wiring the terminal

Comentarios a estos manuales

Sin comentarios