Rockwell-automation 1784-KTCS ControlNET Scanner Installation Instruct Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
ControlNet Scanner Card 5
Publication
1784-5.35 – April 1999
Configuring the Card Hardware
Before you install the card, you must set the card’
s physical addresses for the:
ROM I/O expansion area of the host processor
s system
memory—enables the card and the host computer to exchange data through
the dual-port interface. This is the base memory address.
host processor
s I/O map—enables the card’
s I/O devices to receive
commands from the host computer
. This is the
base I/O space addr
ess.
Y
ou can have as many as four KTCS cards in one computer as long as each card
has dif
ferent base memory and base I/O space addresses.
T
o configure these addresses, you set switches on the card. The card comes
factory-set with these default addresses:
Address Type Address Setting (hex)
base memory D000:0000
base I/O space memory 220
Important: When
deciding which addresses to use, remember that each card
in your computer must have a unique
base memory address and a
unique base I/O space memory address. If another card in the host
computer is using one or both of the factory-set addresses, you
must change a card’
s switch settings to an available address.
If you are: go to:
changing addresses on the card
“Selecting the Base Memory Address
Location” on page 6
using the factory-set addresses “Installing the Card” on page 15
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 31 32

Comentarios a estos manuales

Sin comentarios