Run the 1784-KTx Diagnostics for DOS B-5
1784-6.5.22 - November 1999
Access Diagnostics
At the MS-DOS prompt, type:
cd c:\ktxdiag
and press Enter.
ktxdiag
and press Enter.
!
ATTENTION: You can run diagnostics on only one card or channel
(1784-KTXD) at a time. If you run diagnostics using a memory address
that is incorrect, the computer may lock up. Be certain to run diagnostics
using the correct address setting (see page 2-4 for the memory address(es)
your configured).
If you: Add this to the ktxdiag command:
don’t want to create a KTXDIAG.LOG file -l
are using a monochrome monitor -m
want to see this list of options -h
-?