Publication 1791P-IN002B-EN-P - October 2003
Installation Instructions
Compact
Block
Distributed I/O on
PROFIBUS DP Series D
(Cat. No. 1791P-16B0, -0B16P, -8B8P, -4B4P, -8V8P)
1791P CompactBlock™ I/O modules are stand-alone 24V dc Block
I/O products that communicate via a PROFIBUS DP link. Each PROFIBUS
DP node consists of either one base module or one base module and one
expansion module. Any expansion module can be coupled with any base
module. CompactBlock 1791P consists of only base modules. The expansion
modules are part of the CompactBlock 1791D family of products.
CompactBlock PROFIBUS DP modules must be installed in a secondary
enclosure. Base modules are equipped with 8 to 16 points.
CompactBlock PROFIBUS DP provides sinking and sourcing inputs and
outputs. Sinking inputs are 24V dc IEC Type 3 compatible. Self-protected
24V dc outputs can provide up to 0.5 amp each.
Important User Information
Because of the variety of uses for the products described in this publication,
those responsible for the application and use of these products must satisfy
themselves that all necessary steps have been taken to assure that each
application and use meets all performance and safety requirements, including
any applicable laws, regulations, codes and standards. In no event will
Rockwell Automation be responsible or liable for indirect or consequential
damage resulting from the use or application of these products.
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - PROFIBUS DP Series D

Publication 1791P-IN002B-EN-P - October 2003Installation InstructionsCompactBlock Distributed I/O on PROFIBUS DP Series D(Cat. No. 1791P-16B0, -0B16P

Pagina 2 - ATTENTION

10 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Output Wiring Diagram for 1791P-0B16P and 1791D

Pagina 3

CompactBlock Distributed I/O on PROFIBUS DP Series D 11Publication 1791P-IN002B-EN-P - October 2003Wiring Diagram for the 1791P-4B4P ModuleWiring

Pagina 4 - Installing CompactBlock I/O

12 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Input Wiring Diagram for 1791D-16V0X ModulesCon

Pagina 5

CompactBlock Distributed I/O on PROFIBUS DP Series D 13Publication 1791P-IN002B-EN-P - October 20031. Connect the PROFIBUS DP female 9-pin D-sub c

Pagina 6 - Mount the Block(s)

14 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Select Termination for the ModuleThe terminator

Pagina 7 - DIN Rail Mounting

CompactBlock Distributed I/O on PROFIBUS DP Series D 15Publication 1791P-IN002B-EN-P - October 2003Connect Power to the ModuleTo apply power to th

Pagina 8

16 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 20032. Lift the terminal block out of the base.Inse

Pagina 9

CompactBlock Distributed I/O on PROFIBUS DP Series D 17Publication 1791P-IN002B-EN-P - October 2003Refer to the following table for baud rate spec

Pagina 10 - Publication

18 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Word/Bit DefinitionsThe following table lists t

Pagina 11

CompactBlock Distributed I/O on PROFIBUS DP Series D 19Publication 1791P-IN002B-EN-P - October 2003The following table is an example of the word/b

Pagina 12

2 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Any illustrations, charts, sample programs, and

Pagina 13 - Profibus DP

20 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Following are data tables for internal usage be

Pagina 14

CompactBlock Distributed I/O on PROFIBUS DP Series D 21Publication 1791P-IN002B-EN-P - October 2003Following are data tables on RSLogix500.Maximum

Pagina 15 - Remove the Terminal Block

22 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Maximum Output Data Format (Base Modules -0B16P

Pagina 16 - Insert the Terminal Block

CompactBlock Distributed I/O on PROFIBUS DP Series D 23Publication 1791P-IN002B-EN-P - October 2003Maximum Input Data Format (Base Modules -4B4P)B

Pagina 17 - IMPORTANT

24 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Troubleshoot with the IndicatorsThe 1791P I/O m

Pagina 18 - Word/Bit Definitions

CompactBlock Distributed I/O on PROFIBUS DP Series D 25Publication 1791P-IN002B-EN-P - October 2003SpecificationsSinking or Sourcing Input Specifi

Pagina 19

26 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003PROFIBUS DP Specifications (continued)Fail Safe

Pagina 20

CompactBlock Distributed I/O on PROFIBUS DP Series D 27Publication 1791P-IN002B-EN-P - October 2003General Specifications (continued)Operating Tem

Pagina 21

28 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003General Specifications (continued)Enclosure Mee

Pagina 22

CompactBlock Distributed I/O on PROFIBUS DP Series D 29Publication 1791P-IN002B-EN-P - October 2003North American Hazardous Location Approval The

Pagina 23

CompactBlock Distributed I/O on PROFIBUS DP Series D 3Publication 1791P-IN002B-EN-P - October 2003ATTENTIONEnvironment and EnclosureThis equipment

Pagina 24

30 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Notes:

Pagina 25 - Specifications

CompactBlock Distributed I/O on PROFIBUS DP Series D 31Publication 1791P-IN002B-EN-P - October 2003Notes:

Pagina 26

Publication 1791P-IN002B-EN-P - October 2003 PN 957831-15Supersedes Publication 1791P-IN002A-EN-P - June 2003 Copyright © 2003 Rockwell Automation, In

Pagina 27

4 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003Installing CompactBlock I/OFollow these steps, t

Pagina 28

CompactBlock Distributed I/O on PROFIBUS DP Series D 5Publication 1791P-IN002B-EN-P - October 2003Set the Station Address on the Base ModuleTo set

Pagina 29

6 CompactBlock Distributed I/O on PROFIBUS DP Series D Publication 1791P-IN002B-EN-P - October 2003The switches are read at module power up only.Mo

Pagina 30

CompactBlock Distributed I/O on PROFIBUS DP Series D 7Publication 1791P-IN002B-EN-P - October 2003Panel Mounting1. Place the module against the pa

Pagina 31