Publication 1794-UM066A-EN-P - February 2012
Rack Optimized Discrete I/O 33
4. Click OK to save the configuration.
The digital input module appears in the I/O configuration indented under
the 1794-AENTR adapter.
Edit the Controller Tags
When you add modules to the I/O configuration the system creates tags for those
modules to use in the application program. For the example application you need
to add one more Controller Tag.
1. Double-click the Controller Tags folder in the project window.
The Controller Tags window opens. You see the tags created for the
1794-AENTR and digital I/O modules.
2. Make sure you select the Edit Tags tab at the bottom of the Controller
Tags window, and then create the following tag:
3. Close the Controller Tags window.
Enter the new tag here
Tags created
by the system
Tag Type
Parts_Count Counter