Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 15
Getting Started Chapter 1
Quick Start
This section is provided to help experienced users quickly start using the option
module in Adapter mode or Tap mode. If you are unsure how to complete a step,
refer to the referenced chapter.
Adapter Mode of Operation
Step Action See
1 Review the safety precautions for the option module. Throughout this manual
2 Verify that the PowerFlex drive is properly installed. PowerFlex 750-Series AC Drive
Installation Instructions,
publication 750-IN001
3 Set the option module IP address.
a. When using the option module node address switches, set the IP
address now and proceed with step 4. When using a DHCP or
BOOTP server, or option module parameters instead to set the IP
address, first perform step 3b and all of step 4. Then proceed with
step 5.
b. Verify that the PowerFlex drive is not powered.
Chapter 2
,
Installing the Option Module
4 Install the option module.
a. Insert the option module in drive Port 4, 5, or 6. Use the captive
crews to secure and ground the option module to the drive.
b. Connect the option module to the network by using an Ethernet
cable.
Network Communication Option
Card Installation Instructions,
publication 750COM-IN002
and
Chapter 2
,
Installing the Option Module
5 Apply power to the option module.
a. The option module receives power from the drive. Verify that the
option module is installed correctly and then apply power to the
drive. The status indicators should be green. If they flash red, there
is a problem. See Chapter 7
, Troubleshooting.
b. Configure and verify key drive parameters.
Chapter 2
,
Installing the Option Module
6 Configure the option module for your application.
Set option module parameters for the following functions as required by
your application:
IP address, subnet mask, and gateway address (only when not using
option module node address switches)
Data rate
I/O configuration
Master-Slave or Peer-to-Peer hierarchy
Fault actions
Web enable and features
Chapter 3
,
Configuring the Option Module
7 Configure the controller to communicate with the option module.
Use a controller configuration tool such as RSLogix software to configure
the master on the network to recognize the option module and drive.
Chapter 4
,
Configuring the I/O
8 Create a ladder logic program.
Use a controller configuration tool such as RSLogix software to create a
ladder logic program that enables you to do the following:
Control the option module and connected drive by using I/O.
Monitor or configure the drive by using Explicit messages.
Chapter 5
,
Using the I/O (Adapter mode
only)
Chapter 6
,
Using Explicit Messaging
(Adapter mode only)