Installation Instructions
PowerFlex
®
DC Drive - Frame B Field Circuit
Board
What This Kit Includes
Field circuit board (with plug-in terminal block)
Six screws and washers (for Field board)
Cables for connectors X3 and XFCD on Field board
Static strap
Important:It is highly recommended that the Field SCR module and Dual
Diode module be replaced when replacing the Field circuit
board. The Field SCR and Dual Diode modules are sold as
separate spare part kits.
Tools That You Need
Phillips
®
screwdriver
Flathead screwdriver
Phillips
®
is a registered trademark of Phillips Screw Company.
ATTENTION: Only qualified personnel familiar with DC
drives and associated machinery should plan or implement the
installation, start-up and subsequent maintenance of the system.
Failure to comply may result in personal injury and/or equipment
damage.
ATTENTION: To avoid an electric shock hazard, ensure that all
power to the drive has been removed before performing the
following.
ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - PowerFlex

Installation InstructionsPowerFlex® DC Drive - Frame B Field Circuit Board What This Kit Includes• Field circuit board (with plug-in terminal block)•

Pagina 2 - What You Need to Do

10 PowerFlex® DC Drive - Frame B Field Circuit Board 10. Remove the cables from connectors X3, X4 and XP on the Pulse Transformer board (see Figure 1

Pagina 3 - Step 1: Remove Power

PowerFlex® DC Drive - Frame B Field Circuit Board 11 12. Remove the appropriate gate leads (see Figure 1 on page 6 for location):– For non-regenerativ

Pagina 4 - Protective Covers

12 PowerFlex® DC Drive - Frame B Field Circuit Board 13. Remove the seven screws that secure the Pulse Transformer and Switching Power Supply boards t

Pagina 5 - Step 3: Remove the Pulse

PowerFlex® DC Drive - Frame B Field Circuit Board 13 Step 4: Remove the Existing Field Circuit Board1. Remove the wires from connectors UF, UF1, VF an

Pagina 6

14 PowerFlex® DC Drive - Frame B Field Circuit Board Step 6: Install the Pulse Transformer and Switching Power Supply BoardsInstall the Pulse Transfor

Pagina 7 - Remove connector from XCD_IO

PowerFlex® DC Drive - Frame B Field Circuit Board 15 Step 7: Replace the Protective Covers and Documenting the Change1. Replace the protective covers

Pagina 8 - Loosen screws

Publication 20P-IN012B-EN-P - December 2009Supersedes 20P-IN012A-EN-P - March 2009 Copyright © 2009 Rockwell Automation. All rights reserved. Printed

Pagina 9

2 PowerFlex® DC Drive - Frame B Field Circuit Board What You Need to DoThe Field board is located below the Control board and Control EMI shield and t

Pagina 10 - for location)

PowerFlex® DC Drive - Frame B Field Circuit Board 3 Step 1: Remove Power from the Drive1. Remove and lock-out all incoming power to the drive. ATTENTI

Pagina 11

4 PowerFlex® DC Drive - Frame B Field Circuit Board Step 2: Remove the Protective Covers1. Disconnect the DPI cable from the HIM assembly (if present)

Pagina 12 - Remove screws

PowerFlex® DC Drive - Frame B Field Circuit Board 5 4. Disconnect the HIM Communication cable from the connector on the upper right corner of the Cont

Pagina 13 - Field Circuit Board

6 PowerFlex® DC Drive - Frame B Field Circuit Board Figure 1 Pulse Transformer Circuit Board Layout XSW1XI2CAX3XPTR2 TR1XRX4XYXCD_IOTO5TO3TO6TO1TO4T

Pagina 14 - Transformer and Switching

PowerFlex® DC Drive - Frame B Field Circuit Board 7 3. Remove the cable from connector XTA on the Pulse Transformer board (see Figure 1 on page 6 for

Pagina 15 - Related Documentation

8 PowerFlex® DC Drive - Frame B Field Circuit Board 6. Carefully disconnect the cables from connectors XA, XR and XFCD at the top of the Control board

Pagina 16

PowerFlex® DC Drive - Frame B Field Circuit Board 9 8. Remove the two screws that secure the air flow plate to the top of the Pulse Transformer board

Comentarios a estos manuales

Sin comentarios