Message Operations
Chapter 5
5–5
Table 5.A
Message Attributes
Attri ute
DL20 Line #
Vali esponses
Attri
b
ute
1 2 4
Vali
d R
esponses
Auto Clear x x x Y or N
Auto Repeat x x x Y or N
Chain Message x x x Y or N
Energize Relay x x x Y or N
Flash Message x x x Y or N
Invisible Message x x x Y or N
Message Number
(for chaining to)
x x x 1 to 254
Out to Slave x x x
Y or N
Print Message x x x
Y or N
Scroll Mode x x x
Y or N
Slave Number x x x
1 to 127
Stack Message x x x Y or N
To All Slaves x x x Y or N
Use All Lines x x
Y or N ➁➂
Use Line 1 Only x x
Y or N
Use Line 2 Only x x
Y or N
Use Least-Used Line x x
Y or N
Use Line 3 Only x
Y or N
Use Line 4 Only x
Y or N
Wait Time x x x 0 to 31
The Print Message and Out to Slave attributes are mutually exclusive. The DL20 serial port
can only be used for one function at a time. If one is set to Y, the other becomes N.
Only one line attribute can be set to Y.
If Scroll Mode is set to Y, Use All Lines is automatically forced to N.
Slave Numbers 0,4,6,7,13,18,20,22,43,45, and 48–57 are illegal entries.