Create the Motor Status Screen Chapter 6
10. On the Appearance tab of
the Properties panel:
a. Select White as the List
Selection Text Color.
b. Select Black as the List
Selection Background
Color.
c. Change the Border Width
to 6.
d. Set the Border Style to
Raised.
11. On the List tab of the
Properties panel, set the
Number of Visible Rows
to 2.
12. On the Connections tab,
select Motor_AutoManual
for the Write tag and the
Indicator tag.
13. Resize the list selector if
necessary.
14. Verify the view of the object
on the terminal.