Rockwell-automation 284D On-Machine ArmorStart Accelerator Toolkit Manual de usuario Pagina 85

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 188
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 84
Publication IASIMP-QS015C-EN-P - August 2011 85
ArmorStart Local Control Configuration Chapter 4
Network Input 0 Logic
If there is an IO Connection fault, manual operation from a pendant station or other push buttons will be
allowed. In this example, input 1 of the Boolean OR gate is used for the PLC control. In manual control,
input 0 could be from a sensor on a conveyor belt in which after manually starting the conveyor using a
pendant station, the product will pass the sensor. After a user selected count, the conveyor motor will stop
until another start command is given. Multiple sensors can be used along with logic to start and stop the
motor.
Input 1 Logic
The program also shows one of the ways in which a fault or trip can be programmed via the DeviceLogix
program. For example, a flashing stack light can be an indication of a fault or trip.
Flashing Stack Light Logic
Vista de pagina 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 187 188

Comentarios a estos manuales

Sin comentarios