Chapter 4
Using the Remote I/O Link
414
Rung 2:7
Tells the Color CVIM to display the results page.
| Display |
| Results All Tools |
| Page Page |
| DISPLAY |
| B3 O:021 |
+––––] [––––––––––––––––––––––––––––––––––––––––––––––––––––––––––+–––(U)––––++
| 6 | 02 | |
| |I/O Page | |
| | O:021 | |
| +–––(U)––––+ |
| | 03 | |
| |Results | |
| |Page | |
| | O:021 | |
| +–––(L)––––+ |
| 04 |
Rung 2:8
One must give a lightpen request to change display modes.
| Display |
| All Tools Lightpen |
| Page Request |
| B3 O:020 |
++–––] [––––+–––––––––––––––––––––––––––––––––––––––––––––––––––––––––( )–––––+
| | 4 | 14 |
| |Display | |
| |I/O Page | |
| | B3 | |
| +–––] [––––+ |
| | 5 | |
| |Display | |
| |Results | |
| |Page | |
| | B3 | |
| +–––] [––––+ |
| 6 |
Rung 2:9
| |
+––––––––––––––––––––––––––––––––[END OF FILE]–––––––––––––––––––––––––––––––––+
| |