Publication 2711-6.10 This document describes how to connect and configurecommunications for the C
ControlNet Communications10Publication 2711-6.10Configuring ControlNet CommunicationsControlNet communication parameters are accessed from theTermina
ControlNet Communications 11Publication 2711-6.10Use the PanelBuilder tag editor to assign tag addresses. ControlNettag addresses use the same forma
ControlNet Communications12Publication 2711-6.10PanelBuilder provides automatic conversions between DH+ andControlNet applications. To convert appli
ControlNet Communications 13Publication 2711-6.10To download applications through the PanelView ControlNetport:➁ Choose Download from the Application
ControlNet Communications14Publication 2711-6.10The application printout for ControlNet provides the followinginformation:• configuration data• tag d
ControlNet Communications 15Publication 2711-6.10PanelBuilder Translation Error MessagesMessage Recommended Action / NotesTranslation Failure Contact
ControlNet Communications16Publication 2711-6.10The following tables lists error messages and codes specific toControlNet communications. For all ot
ControlNet Communications 17Publication 2711-6.10Terminal Alert CodesThese messages appear on the terminal screen as DC Error = xx andalert the user
ControlNet Communications18Publication 2711-6.10Internal errors are displayed in an error banner as shown below:If an internal error occurs:1. Write
ControlNet Communications 19Publication 2711-6.10AdapterControlNet device which responds to scanner messages (sometimescalled a slave device).BridgeD
ControlNet Communications2Publication 2711-6.10The following documentation provides additional information aboutinstalling, configuring and using you
ControlNet Communications20Publication 2711-6.10PLCAcronym for Programmable Logic Controller identified by the 1785-Catalog number prefix.RepeaterTwo
Publication 2711-6.10 – April 1998Rockwell Automation helps its customers receive a superior return on their investment by bringingtogether leading br
ControlNet Communications 3Publication 2711-6.10The PanelView terminal supports release 1.5 of ControlNet.Unscheduled (peer) addressing of tags is su
ControlNet Communications4Publication 2711-6.10Shown below is a typical ControlNet network with a PanelView 900installed on a network drop.PanelView
ControlNet Communications 5Publication 2711-6.10Refer to the following pinout information to connect the PanelViewto a ControlNet network.Important:
ControlNet Communications6Publication 2711-6.10The PanelView terminal displays ControlNet settings and allowschanges to the the Node Address and Inte
ControlNet Communications 7Publication 2711-6.10Serial NumberRead only field that displays the 32 bit serial number of thePanelView. The serial numb
ControlNet Communications8Publication 2711-6.10The following ControlNet related fields may be placed on anapplication screen using internal tags. Th
ControlNet Communications 9Publication 2711-6.10Creating a ControlNet application includes:1. Selecting a ControlNet terminal when creating the appli