Rockwell-automation 5370-UPK CVIM USER-PAK Option Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 5370-UPK CVIM USER-PAK Option. Rockwell Automation 5370-UPK CVIM USER-PAK Option User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 142
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - USER–PAK Option

ALLEN-BRADLEYBulletin 5370 CVIMUSER–PAK Option(Catalog No. 5370–UPK)User Manual

Pagina 2 - Important User Information

Chapter 2Introduction to the USER–PAK Option2–2The USER–PAK option enables access to four different levels of interaction;we refer to these different

Pagina 3 - Chapter 2

Chapter 8Defining Strings for Serial Ports and Viewports8–24Selecting the IntervalOnce you have defined the event source and source condition, you can

Pagina 4 - Displays

Chapter 8Defining Strings for Serial Ports and Viewports8–25Selecting the Toolset(s)The string will be processed at the completion of each inspection

Pagina 5 - Ports and Viewports

Chapter 8Defining Strings for Serial Ports and Viewports8–26The Repeat String feature enables the CVIM module to repeat a particularstring multiple ti

Pagina 6 - Table of Contents

Chapter 8Defining Strings for Serial Ports and Viewports8–27You can use the # (index) character in the string; when the # is placed in thestring text,

Pagina 7 - Using This Manual

Chapter 8Defining Strings for Serial Ports and Viewports8–28Example of Using the Repeat String and Index CharacterSerial Port: This section provides

Pagina 8 - Using This Manual

Chapter 8Defining Strings for Serial Ports and Viewports8–29The second # is used with the data code – g# ; used this way, the indexcauses the transmis

Pagina 9

Chapter 8Defining Strings for Serial Ports and Viewports8–30This section provides an example of a serial port message string, for thepurpose of demons

Pagina 10 - Modifications

Chapter 8Defining Strings for Serial Ports and Viewports8–31and g2, which cause the transmission of the gage 1 and gage 2 results(109 and 112), respec

Pagina 11 - Messages

Chapter 8Defining Strings for Serial Ports and Viewports8–32Finally, recall that, for this example, the string is to be transmitted onlywhen the inspe

Pagina 12 - Custom Runtime Displays

Chapter 8Defining Strings for Serial Ports and Viewports8–33This section examines the example viewport display shown below, anddescribes how the vario

Pagina 13 - Connect and Use a Mouse

Chapter 2Introduction to the USER–PAK Option2–3Text Modification: The USER–PAK option enables the ADMINISTRATORto modify the text of menu items, and o

Pagina 14 - Installation

Chapter 8Defining Strings for Serial Ports and Viewports8–34Example 1 – Creating a Special CharacterThe labels for the Graph viewport (0→ and 63→ )

Pagina 15 - Chapter 3

Chapter 8Defining Strings for Serial Ports and Viewports8–35Example 2 – Using the Change Color CodeThe Graph viewport, which plots the results of wind

Pagina 16

Chapter 8Defining Strings for Serial Ports and Viewports8–36Example 3 – Using the Draw Line CodeA draw line code was used to draw the horizontal line

Pagina 17 - Using the Setup Card

Chapter 8Defining Strings for Serial Ports and Viewports8–37Example 4 – Using Repeat String and # (Index) CharacterThe first column in the viewport di

Pagina 18 - Accessing Setup Mode

Chapter 8Defining Strings for Serial Ports and Viewports8–38In order to use the Repeat String feature, you must define the range (that is,the Start, E

Pagina 19 - Security

Chapter 8Defining Strings for Serial Ports and Viewports8–39Example 5 – Using Data Codes and # (Index) CharacterThe second and third columns in the vi

Pagina 20 - Accessing the Setup Mode

Chapter 8Defining Strings for Serial Ports and Viewports8–40• Literal text (in this case, spaces enclosed in quotes) is used to providespacing between

Pagina 21 - Security Levels

Chapter 8Defining Strings for Serial Ports and Viewports8–41Example 6 – Conditionally Displaying a Text StringThe “PART REJECTED” string in the viewpo

Pagina 22 - Table 4.A

Chapter 8Defining Strings for Serial Ports and Viewports8–42Recall that we also need to create a second string which will have the effectof erasing th

Pagina 23 - Changing Passwords

Chapter 8Defining Strings for Serial Ports and Viewports8–43Here are the different elements of the string text:• The string text begins with a plot li

Pagina 24 - Security level selected

Chapter 2Introduction to the USER–PAK Option2–4Within each message you can send literal text, results and other data onspecific tools, statistical dat

Pagina 25 - Chapter 4

A–B9Chapter9–1Using Copy and PasteContentsChapter Objectives 9–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using

Pagina 26 - Lost Passwords – Using

Chapter 9Using Copy and Paste9–2Note these additional considerations regarding the Copy/Paste features:• When you copy the settings of the source into

Pagina 27

Chapter 9Using Copy and Paste9–3• Pick the Next box to select window 2.Window 2 selected• Pick the Paste box to copy the settings from window 1, the s

Pagina 28 - Modifying the CVIM Menus

Chapter 9Using Copy and Paste9–4• Pick the Next box to select the destination viewport – viewport 2.• Check the Paste box. If the Paste box is disab

Pagina 29 - Chapter 5

A–B10Chapter10–1Loading CVIM / USER–PAK ConfigurationsContentsChapter Objectives 10–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 30

Chapter 10Loading CVIM / USER–PAK Configurations10–2• Pick the appropriate box (Menus, Viewports / Serial Ports, Inspection,or All CVIM) on the respec

Pagina 31 - Example – Menu Item Deletion

Chapter 10Loading CVIM / USER–PAK Configurations10–3The procedure for loading a portion of a configuration will depend on whichportion you want to loa

Pagina 32 - The Cascade Effect

Chapter 10Loading CVIM / USER–PAK Configurations10–4You can check the remaining allotted memory available for these features.To do this:• Pick Env. →

Pagina 33 - Text Modification

A–BAAppendixA–1Connecting and Using a MouseWith the USER–PAK option installed, the CVIM module user has the optionof connecting and using a mouse, ins

Pagina 34

Appendix AConnecting and Using a MouseA–2• Pick the I/O box to open the I/O menu.• Pick the RS/232 A box, if you are connecting the mouse to serial po

Pagina 35

Chapter 2Introduction to the USER–PAK Option2–5With the USER–PAK option installed, you can copy the settings from onegage or window to another using

Pagina 36

Appendix AConnecting and Using a MouseA–3Types of Mouse and Trackball SupportedThe CVIM module (with the USER–PAK option installed) supports mostseria

Pagina 37 - Editing Text

A–BBAppendixB–1Character CodesThis appendix lists the character codes that can be used with the / (charactercode) indicator to generate special charac

Pagina 38 - With EOL

Appendix BCharacter CodesB–2Table B.2 Character Codes (Serial Ports and Viewports) 1, 2, 3CodeCharacterCodeCharacterCodeCharacterCodeCharacterCodeCha

Pagina 39

A–BCAppendixC–1ASCII Commands for the USER–PAK OptionWith the USER–PAK option installed, the CVIM module recognizesadditional ASCII commands through i

Pagina 40

Appendix CASCII Commands for the USER–PAK OptionC–2Force Print for Serial Port StringsFor serial port strings, the Force Print command takes this form

Pagina 41 - • Pick the Text String box

Appendix CASCII Commands for the USER–PAK OptionC–3Read String Data CommandThe Read String Data command can be used to obtain the defined attributesan

Pagina 42 - Memory Requirement

Appendix CASCII Commands for the USER–PAK OptionC–4The enhanced Write Display command takes this format (where the nparameter is the enhancement):>

Pagina 43 - Serial Port Messages

A–BIndexI–1AAccessing the setup mode, 3–5, 4–2Archiving text modifications, 5–15ASCII commands, C–1Force print, C–1Read string data, C–3Suspend / resu

Pagina 44

IndexI–2DData codes, 8–4Example, serial port, 8–30Example, text and tool viewports, 8–35, 8–39,8–43Default password, 4–6Lost password, 4–9Define strin

Pagina 45 - Previous / Next boxes

IndexI–3F (cont.’d)Formula indicator (cont.’d)As draw line parameter, 8–15Examples, text and tool viewport, 8–42, 8–43Formula results, repeat string

Pagina 46 - Defining Strings

A–B3Chapter3–1InstallationContentsChapter Objectives 3–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Two USER–P

Pagina 47 - Defining the Serial Port

IndexI–4RRead string data command, C–3Related publications, 1–2Repeat string, using, 8–26Parameters, setting, 8–27Using formulas for, 8–29Using with i

Pagina 48 - • Buffer: Wait/No Wait

IndexI–5VValid elements of string text, 8–3. See also Elementsof string text, validVariable, graph viewportDefining, 7–20Color, selecting the, 7–21St

Pagina 49 - Buffer: No wait

1992 Allen-Bradley CompanyALLEN-BRADLEYWith offices in major cities worldwide.WORLD HEADQUARTERSAllen-Bradley1201 South Second StreetMilwaukee, WI 53

Pagina 50 - RS–232 Port Connections

Chapter 3Installation3–2firmware revision is listed on the title banner on the monitor screenfollowing powerup).One–Time Installation: You need only

Pagina 51 - Baud rate selected

Chapter 3Installation3–3The top three LEDs on the CVIM module indicate the progress of thethree–phase loading process, as follows:LEDsUSER–PAK Loading

Pagina 52 - Runtime Displays

Chapter 3Installation3–4To access most, but not all, of the USER–PAK features while in setup mode,the Setup card must be inserted.To insert the Setup

Pagina 53 - Chapter 7

Chapter 3Installation3–5Upon installation of the USER–PAK option, access to the setup moderequires the use of a password. The password is entered thr

Pagina 54 - Defining the Viewport

A–B4Chapter4–1Getting Started / Using the Security LevelsContentsChapter Objectives 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 55 - Define Viewport menu

ALLEN-BRADLEYSolid state equipment has operational characteristics differing from those ofelectromechanical equipment. “Application Considerations for

Pagina 56 - Text Viewport

Chapter 4Getting Started / Using the Security Levels4–2instance, a system “administrator” can be designated; this person would haveaccess to the ADMIN

Pagina 57 - Type box

Chapter 4Getting Started / Using the Security Levels4–3Listed below are further considerations for accessing the setup mode:First Time Entry – Default

Pagina 58

Chapter 4Getting Started / Using the Security Levels4–4Table 4.AFunctions/Features at each Security LevelFunctions/Security LevelFunctions/FeaturesAdm

Pagina 59 - Display Contents

Chapter 4Getting Started / Using the Security Levels4–5Security Level IndicationWhile in setup mode with the USER–PAK option installed, the icons in t

Pagina 60 - Color Selection

Chapter 4Getting Started / Using the Security Levels4–6For example, if a particular password is used for both theADMINISTRATOR and MANAGER levels, usi

Pagina 61

Chapter 4Getting Started / Using the Security Levels4–7Once you enter the new password, the keyboard prompts you to reenterthe password in order to ve

Pagina 62 - Erase Port Data box

Chapter 4Getting Started / Using the Security Levels4–8The USER–PAK option allows the ADMINISTRATOR to disable security(that is, remove the password r

Pagina 63 - Viewport Contents

Chapter 4Getting Started / Using the Security Levels4–9To enter the setup mode using the Installation / Key card, complete thesesteps:• If the CVIM mo

Pagina 64 - Using the Define String Menu

A–B5Chapter5–1Modifying the CVIM MenusContentsChapter Objectives 5–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . De

Pagina 65 - Down direction

Chapter 5Modifying the CVIM Menus5–2Deletion ProcedureMarking an item for deletion involves just a few basic steps (the followingsteps assume the ADMI

Pagina 66

A–BUSER–PAK OptionUser ManualTable of ContentsiChapter 1Chapter Objectives 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 67 - Handle appears when

Chapter 5Modifying the CVIM Menus5–3where it normally appears, for both toolsets. For example, if you delete acolor selection item from the Color Se

Pagina 68 - The Copy and Paste Features

Chapter 5Modifying the CVIM Menus5–4Example – Menu Item DeletionSeveral items on the Define Window menu are marked for deletion, asshown below:“Trash

Pagina 69 - Defining Graph Viewports

Chapter 5Modifying the CVIM Menus5–5The Cascade EffectIf all items except one have been deleted from a menu, and the oneremaining menu item has a thre

Pagina 70 - Previous box

Chapter 5Modifying the CVIM Menus5–6The USER–PAK option enables you to modify the text of menu items, and ofon–screen messages such as the help messag

Pagina 71 - Defining the Variable

Chapter 5Modifying the CVIM Menus5–7Text String SearchTo use the Text String method for accessing a dictionary entry to modify,follow this procedure:•

Pagina 72

Chapter 5Modifying the CVIM Menus5–8 When you pick the Ret key, one of two results can occur:(1) No dictionary entry is found to contain the text yo

Pagina 73 - Defining the Graph

Chapter 5Modifying the CVIM Menus5–9• Pick the Ret key. One of two results can occur:(1) If the dictionary ID number you entered is not defined, the

Pagina 74 - • Pick the Define Graph box

Chapter 5Modifying the CVIM Menus5–10Editing TextAfter you find the entry you want to modify (the entry is displayed in theNew Text: field), edit the

Pagina 75 - Upper box

Chapter 5Modifying the CVIM Menus5–11use the EOL character to create enough lines to account for all thelines in the menu item, in order to have the b

Pagina 76

Chapter 5Modifying the CVIM Menus5–12Here are some additional considerations when editing text:Multiple Menu Usage of a Dictionary Entry: In some cas

Pagina 77 - String Text

USER–PAK OptionUser ManualTable of ContentsiiSearching for Text 5–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Text St

Pagina 78 - String syntax message

Chapter 5Modifying the CVIM Menus5–13Examples of Modifying TextExample 1: We want to change the runtime menu item Result Page toGage Result, a name w

Pagina 79 - Valid Elements of String

Chapter 5Modifying the CVIM Menus5–14Example 2: We want to change the Env.→ System→ Units menu item,CM, to MM to reflect the actual range of measurem

Pagina 80 - Data Codes

Chapter 5Modifying the CVIM Menus5–15Menu modifications, if saved internally, can be accessed in a separateconfiguration called the Menus configuratio

Pagina 81 - Table 8.A (pt. 2 of 3)

A–B6Chapter6–1Creating Custom Serial Port MessagesContentsChapter Objectives 6–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 82 - Table 8.A (pt. 3 of 3)

Chapter 6Creating Custom Serial Port Messages6–2How many strings can be defined?The CVIM module can store up to 340 strings, depending on how much oft

Pagina 83

Chapter 6Creating Custom Serial Port Messages6–3Basic Steps for Creating Custom Serial Port MessagesTo create a custom serial port message:• Insert th

Pagina 84

Chapter 6Creating Custom Serial Port Messages6–4– literal text, and/or codes of various types – for the string (seeChapter 8 for more information on e

Pagina 85

Chapter 6Creating Custom Serial Port Messages6–5during setup to test the results of your current string text entry, and to testyour serial port connec

Pagina 86 - Field Formatting Codes

Chapter 6Creating Custom Serial Port Messages6–6The Define Serial Port menu consists of two items:• Erase Port Data• Buffer: Wait/No WaitErase Port Da

Pagina 87

Chapter 6Creating Custom Serial Port Messages6–7Picking the Buffer box toggles the setting between Buffer: Wait and Buffer:No wait.Buffer: WaitThe tw

Pagina 88

USER–PAK OptionUser ManualTable of ContentsiiiSetting the Style 7–20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selecting

Pagina 89 - Conditional Color–coding

Chapter 6Creating Custom Serial Port Messages6–8for a single inspection must be limited to 128 bytes or less, and that, evenif messages are so limited

Pagina 90 - Draw Line Codes

Chapter 6Creating Custom Serial Port Messages6–9Selecting Serial Port ParametersIn order to use a serial port for serial messages, you must configure

Pagina 91

A–B7Chapter7–1Creating Custom Runtime DisplaysContentsChapter Objectives 7–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 92

Chapter 7Creating Custom Runtime Displays7–2How do you create custom runtime displays?You create custom runtime displays using the Config. Output feat

Pagina 93

Chapter 7Creating Custom Runtime Displays7–3This section describes the initial steps to use in defining a viewport. Todefine a viewport:• Insert the S

Pagina 94 - Change Color Codes

Chapter 7Creating Custom Runtime Displays7–4• Pick the Define Viewport . . . box to access the Define Viewport menu:Define Viewport boxDefine Viewport

Pagina 95 - Color Codes for Strings

Chapter 7Creating Custom Runtime Displays7–5• Tool – The Tool viewport is much like the Text type, in terms of content– it can display literal text, t

Pagina 96 - Defining the Event

Chapter 7Creating Custom Runtime Displays7–6To select the viewport Type:• Pick the Type box on the Define Viewport menu – picking the Typebox, you can

Pagina 97 - Source condition

Chapter 7Creating Custom Runtime Displays7–7• Pick and “drag” the handles to reshape and reposition the viewport (referto the window placement procedu

Pagina 98

Chapter 7Creating Custom Runtime Displays7–8Here are additional considerations when selecting and positioning viewports:Position Limitation: The bott

Pagina 99 - Source condition box

USER–PAK OptionUser ManualTable of ContentsivChapter 10Chapter Objectives 10–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 100 - Print Every ... box

Chapter 7Creating Custom Runtime Displays7–9Here is an additional consideration when selecting border and backgroundcolors: Colors during setup: The

Pagina 101 - Chapter 8

Chapter 7Creating Custom Runtime Displays7–10 “Page” Displays: During run mode, any Text or Graph viewportassigned to “Page” displays – that is, the

Pagina 102 - Using Repeat String

Chapter 7Creating Custom Runtime Displays7–11Here is an additional consideration when selecting Page Numbers: Select at least one box: You must selec

Pagina 103 - Repeat String menu

Chapter 7Creating Custom Runtime Displays7–12This section discusses how to define Text and Tool viewport contents – bothtypes are discussed together b

Pagina 104 - Transmitted Strings:

Chapter 7Creating Custom Runtime Displays7–13 Note: All strings for a selected viewport are displayed on the screen.The currently selected string is

Pagina 105 - Newline Character

Chapter 7Creating Custom Runtime Displays7–14The Define String menu allows access to the following menu items:• Repeat String: Select this item to en

Pagina 106 - Message Example

Chapter 7Creating Custom Runtime Displays7–15Selecting String WidthYou further define appearance of the string by selecting the string width. Tochang

Pagina 107 - Format Codes – (3)

Chapter 7Creating Custom Runtime Displays7–16Here are additional considerations when selecting string colors: Override for String Color: The string

Pagina 108 - Tool Set 1 selected

Chapter 7Creating Custom Runtime Displays7–17 Note: When using the Pick & Place item for a string within a Toolviewport, you can position the st

Pagina 109 - Examples

Chapter 7Creating Custom Runtime Displays7–18This section discusses how to define Graph viewports. Graph viewportsprovide the capability to display i

Pagina 110 - Example 1

A–B1Chapter1–1 Using This ManualContentsChapter Objectives 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual C

Pagina 111 - Example 2

Chapter 7Creating Custom Runtime Displays7–19right as the variables are plotted from left to right (Note: The plotting ofvariables cannot be observed

Pagina 112 - Example 3

Chapter 7Creating Custom Runtime Displays7–20Defining the VariableAfter selecting a specific variable, you next define the variable using theDefine Gr

Pagina 113 - Example 4

Chapter 7Creating Custom Runtime Displays7–21setting other than Disabled (Dot or Line), which selects the style, enablesthe variable, and also enables

Pagina 114 - Increment value

Chapter 7Creating Custom Runtime Displays7–22Selecting the Variable ToolYou must select the specific tool whose results are plotted in the Graphviewpo

Pagina 115 - Example 5

Chapter 7Creating Custom Runtime Displays7–23To access the Define Graph menu:• Pick the Define Graph box.Define Graph menuDefine Graph boxUpper limit

Pagina 116 - • Increment: 1

Chapter 7Creating Custom Runtime Displays7–24Note these additional considerations when setting Upper and Lower limits:• The limits you set are for the

Pagina 117 - Master Range selected

Chapter 7Creating Custom Runtime Displays7–25The Event you define is in effect for all variables enabled for the Graphviewport – you cannot specify an

Pagina 118 - Tool Viewport String

A–B8Chapter8–1Defining Strings for Serial Ports and ViewportsContentsChapter Objectives 8–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 119

Chapter 8Defining Strings for Serial Ports and Viewports8–2• Pick the Ret key when finished entering or modifying text, which entersthe string into me

Pagina 120 - Using Copy and Paste

Chapter 8Defining Strings for Serial Ports and Viewports8–3The strings you create will consist of one or more elements; these elementsdefine the corre

Pagina 121 - Window 1 selected

Chapter 1Using This Manual1–2Before using this manual, you should be familiar with the CVIM modulefeatures and the procedures used in configuring the

Pagina 122 - Paste box indicates

Chapter 8Defining Strings for Serial Ports and Viewports8–4Valid Characters for Literal Text: Any character(s) that you enclose inquotes will be sent

Pagina 123 - (1/2 – viewport 1, string 2)

Chapter 8Defining Strings for Serial Ports and Viewports8–5Table 8.A (pt. 2 of 3)Data CodesData Code1Subcodes (.s)1Description of fieldRLn.sRLn (no

Pagina 124 - Configurations

Chapter 8Defining Strings for Serial Ports and Viewports8–6Table 8.A (pt. 3 of 3)Data CodesData Code1Subcodes (.s)1Description of fieldSn s2Sn (no s

Pagina 125 - Load Config ( Int )

Chapter 8Defining Strings for Serial Ports and Viewports8–7Special Characters: N, /, %, #These four characters have special functionality within the s

Pagina 126 - Checking Available

Chapter 8Defining Strings for Serial Ports and Viewports8–8/ Character Code IndicatorSerial Ports: You can transmit any character from the ASCII char

Pagina 127 - Chapter 10

Chapter 8Defining Strings for Serial Ports and Viewports8–9Serial Ports: You can use the formula indicator with the character codeindicator (see “/ C

Pagina 128 - Connecting and Using a Mouse

Chapter 8Defining Strings for Serial Ports and Viewports8–10Example – We want to display the statistical mean for gages 1–8. To do this,we would use

Pagina 129 - Using a Mouse

Chapter 8Defining Strings for Serial Ports and Viewports8–11the result of the gage 1, and limits the field for that result to three places inthe viewp

Pagina 130 - Appendix A

Chapter 8Defining Strings for Serial Ports and Viewports8–12(–x) The “minus” sign (– ) placed within the format code specifies thevalue will be left j

Pagina 131 - Character Codes

Chapter 8Defining Strings for Serial Ports and Viewports8–13Examples: Assume formula 1 result = 1234.56This codetransmits (or displays) this field:F1(

Pagina 132 - Appendix B

A–B2Chapter2–1Introduction to the USER–PAK OptionContentsChapter Objectives 2–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 133 - ASCII Commands

Chapter 8Defining Strings for Serial Ports and Viewports8–14For example, suppose the following string text is entered, and is assigned thecolor Blue u

Pagina 134 - Write String Data Command

Chapter 8Defining Strings for Serial Ports and Viewports8–15Note: For Tool viewports, the viewport boundaries are that of the screen, sothat the top

Pagina 135 - Read String Data Command

Chapter 8Defining Strings for Serial Ports and Viewports8–16may be preferable to use the Tool type viewport when using formularesults for line drawing

Pagina 136 - Appendix C

Chapter 8Defining Strings for Serial Ports and Viewports8–17Draw Line Code Position Priority: The draw line coordinates have priorityover the string

Pagina 137 - C (cont.’d)

Chapter 8Defining Strings for Serial Ports and Viewports8–18Plot Line CodesYou can use plot line codes to draw lines within a viewport (either Text or

Pagina 138 - E (cont.’d)

Chapter 8Defining Strings for Serial Ports and Viewports8–19Table 8.BColor Codes for StringsNo. Text Color Tool Color1 Green Green2 Yellow Yellow3 Red

Pagina 139

Chapter 8Defining Strings for Serial Ports and Viewports8–20Summary of Codes and IndicatorsTable 8.C provides a summary of the special characters and

Pagina 140 - S (cont.’d)

Chapter 8Defining Strings for Serial Ports and Viewports8–21To begin to define the event for a string, first access the Event menu. Foreither a viewp

Pagina 141 - V (cont.’d)

Chapter 8Defining Strings for Serial Ports and Viewports8–22During run mode, upon completion of an inspection, the CVIM checks thespecified event sour

Pagina 142 - ALLEN-BRADLEY

Chapter 8Defining Strings for Serial Ports and Viewports8–23Enter key is picked. In this case, the Event will be tested for eachincrement of the inde

Comentarios a estos manuales

Sin comentarios