Chapter 2
Introduction to the USERPAK Option
24
Within each message you can send literal text, results and other data on
specific tools, statistical data, and other information. You also define the
conditions under which a serial message is transmitted the message can be
sent after each inspection, or only upon certain conditions, such as the failure
of a specific tool, for instance.
Runtime displays are those displays which appear on the monitor while the
CVIM is operating in run mode. You create custom runtime displays by
configuring viewports, using the Config. Output feature, which becomes
available on the Env. menu with the USERPAK option installed. You select
display borders and background color, and you define the viewport contents.
Viewports can contain text, numerical data, line graphics, and realtime
graphs. You also define the conditions under which viewport contents are
displayed the contents can be displayed after each inspection, or only upon
certain conditions, such as the failure of a specific tool, for instance.