Chapter 3
Installation
33
The top three LEDs on the CVIM module indicate the progress of the
threephase loading process, as follows:
LEDs
USERPAK Loading Phase
LEDs
1
2 3
Pass/Fail
Redtoyellow
togreen
Green
Redtoyellow
togreen
Trigger 1 Green Green Off
Trigger 2 Off Green Green
The loading process requires about 45 seconds, with each phase taking
about 15 seconds. When the loading process is complete, the CVIM
module begins its normal powerup sequence.
Verify that the USERPAK option is installed by checking the title banner
on the monitor after powerup; if the USERPAK option is installed,
there is a message on the banner indicating the presence of the
USERPAK option.
Remove the Installation / Key card from the Archive Memory slot.
Card Security: Because the Installation / Key card can be used to
override the CVIM system security (see Chapter 4), it is suggested that
this card be kept in a secure place when not in use, and that access to this
card be allowed only to the appropriate authorized personnel.