Publication 56AMXN-IN002A-EN-P November 2002 Installation Instructions ControlLogix AutoMax DCSNet and AutoMax Remote I/O Communication Interface Mod
10 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Installing or Removing the Module While Power Is Applied Versions of the 56AM
DCSNet/RE RIO Module 11 Publication 56AMXN-IN002A-EN-P November 2002 Install the Module Do not force the module into the backplane connector. If yo
12 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Removing or Replacing the Module (When Applicable) If you are replacing an
DCSNet/RE RIO Module 13 Publication 56AMXN-IN002A-EN-P November 2002 Wire the Connector for the AutoMax Network Use a drop cable, 612574-36R, availa
14 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Check Power Supply and Module Status The rack power supply indicator should b
DCSNet/RE RIO Module 15 Publication 56AMXN-IN002A-EN-P November 2002 Interpreting the Alphanumeric Display The 56AMXN/B module displays alphanumeric
16 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Message Description Error: Heard Another RIO Master The module is configured
DCSNet/RE RIO Module 17 Publication 56AMXN-IN002A-EN-P November 2002 Interpreting the LED Status Indicators The three LED status indicators on the m
18 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 OK LED – Module Health A bicolor OK LED indicates module health. A red LED in
DCSNet/RE RIO Module 19 Publication 56AMXN-IN002A-EN-P November 2002 Hazardous Location information The following information applies when operating
2 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Important User Information Because of the variety of uses for the products des
20 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Specifications Parameter Specification Module Location ControlLogix chassis
DCSNet/RE RIO Module 21 Publication 56AMXN-IN002A-EN-P November 2002 Local Drive Solutions Contact Directory New EnglandPh. 508.357.8431Fax 508.48
22 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002
DCSNet/RE RIO Module 23 Publication 56AMXN-IN002A-EN-P November 2002
24 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 www.rockwellautomation.com Corporate Headquarters Rockwell Automat
DCSNet/RE RIO Module 3 Publication 56AMXN-IN002A-EN-P November 2002 Throughout this manual we use the following notes to make you aware of safety co
4 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Understand Compliance to European Union Directive If this product bears the CE
DCSNet/RE RIO Module 5 Publication 56AMXN-IN002A-EN-P November 2002 Enclosure and Environmental Requirements Specific To This Product The 56AMXN/B i
6 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 ATTENTION Identify Module Features Refer to the following figure to identify t
DCSNet/RE RIO Module 7 Publication 56AMXN-IN002A-EN-P November 2002 Set the Network Type and Node Address Switches Before you install the module, yo
8 DCSNet/RE RIO Module Publication 56AMXN-IN002A-EN-P November 2002 Prepare the Chassis for Module Installation Before you install the 56AMXN/B mo
DCSNet/RE RIO Module 9 Publication 56AMXN-IN002A-EN-P November 2002 Determine Module Slot Location The figure below shows chassis slot numbering in