Rockwell Automation Publication 842E-UM001A-EN-P May 2012 25
Configuring the encoder for your EtherNet/IP network Chapter 5
5. Disable DHCP: click once on the encoder in the relation list to highlight
it. Then click Disable BOOTP/DHCP. This instructs the 842E encoder
to retain the IP address at the next power cycle.
Wait for the status message to show that the command was successfully
sent. If the message does not appear, repeat this step.
6. Click File > Save As to save the relationship, if desired.
7. Cycle the power to the 842E encoder. You should no longer see the 842E
encoder appear in the request history panel.
From a DOS prompt, you can ping the new address. The response should be
4 packets sent, 4 packets received, and 0 lost.