Rockwell-automation AADvance Controller System Build Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation AADvance Controller System Build. Rockwell Automation AADvance Controller System Build User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 130
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
AADvance
The Next Step in Automation
AADvance Controller
System Build Manual
System Build ManualSystem Build Manual
System Build Manual
Issue: 08
Issue: 08Issue: 08
Issue: 08
DOCUMENT: 553632
DOCUMENT: 553632DOCUMENT: 553632
DOCUMENT: 553632
(
((
(ICSTT
ICSTTICSTT
ICSTT-
--
-RM448_EN_P
RM448_EN_PRM448_EN_P
RM448_EN_P)
))
)
Vista de pagina 0
1 2 3 4 5 6 ... 129 130

Indice de contenidos

Pagina 1 - System Build Manual

AADvance The Next Step in Automation AADvance Controller System Build ManualSystem Build ManualSystem Build ManualSystem Build Manual Issue: 08I

Pagina 2

x Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Upgrade the Processor Module Recovery Mode F

Pagina 3

4-20 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Upgrade Processor OS, FPGAFPGA, LSP and B

Pagina 4

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-21 4) Browse to the device in the RSLinx window 5) Select the firmware revision for t

Pagina 5

4-22 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) 6) Check the summary details, click F

Pagina 6

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-23  A progress bar is displayed Note: if the processor is not in the Recovery Mode the

Pagina 7

4-24 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Setting Up the Controller IP Address

Pagina 8 - Contents

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-25 Double-clicking on an entry in the list lets you inspect the resource and IP address sett

Pagina 9

4-26 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) 3) Do not use an office network. Use an

Pagina 10

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-27  The resource and IP Address dialog box opens. 6) Enter the resource value into the R

Pagina 11 - Product Overview

4-28 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) 2) Make sure the program enable key is i

Pagina 12

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-29  Returning to the main window of the utility, the controller status will show In Progre

Pagina 13

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-1 This chapter provides an overview of a controller and briefly describes its major componen

Pagina 14

4-30 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) This page intentionally left bl

Pagina 15

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 5-1 Functional acceptance testing, also known as factory acceptance testing or integration tes

Pagina 16

5-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Controller ConfigurationController Configu

Pagina 17

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 6-1 In This ChapterIn This ChapterIn This ChapterIn This Chapter About Dismantling a System

Pagina 19

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 7-1 Bases Part No. Part Description T9100 Processor base unit T9300 I/O base unit (3 way)

Pagina 20

7-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) T9831 Analogue input TA, 16 channel, simp

Pagina 21

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 7-3 T9903 Replacement coding pegs (pack of 20) T9904 Re

Pagina 22

7-4 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) T9902: SMF Omni-Block, Surface Mount Fuse

Pagina 23

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 8-1 Glossary of Terms AAAA accuracyaccuracyaccuracyaccuracy The degree of conformit

Pagina 24

1-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) All of the configurations are readily achi

Pagina 25

8-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) blanking coverblanking coverblanking cover

Pagina 26

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 8-3 Chapter 7 Glossary of Terms consumerconsumerconsumerconsumer The consuming control

Pagina 27

8-4 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) fault reset buttonfault reset buttonfault

Pagina 28

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 8-5 Chapter 7 Glossary of Terms hot swaphot swaphot swaphot swap See live insertion. I

Pagina 29

8-6 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) MMMM manual call pointmanual call point

Pagina 30

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 8-7 Chapter 7 Glossary of Terms processor moduleprocessor moduleprocessor moduleprocessor

Pagina 31 - Before You Begin

8-8 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) SFFSFFSFFSFF Safe Failure Fraction. Giv

Pagina 32

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 8-9 Chapter 7 Glossary of Terms UUUU UUUU Rack unit. A unit of measure used to descr

Pagina 34

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 9-1 For more information about the AADvance system refer to the associated Rockwell Automation

Pagina 35

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-3 The AADvance controller is developed and built for IEC 61131 compliance and includes suppo

Pagina 36

9-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) PFH avg and PFDavg Data This document cont

Pagina 37

1-4 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Certification for use in Hazardous Environ

Pagina 38

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-5

Pagina 39

1-6 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) The AADvance controller has also been eva

Pagina 40

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-7 AADvanceDiscover UtilityAADvanceDiscover UtilityAADvanceDiscover UtilityAADvanceDiscover

Pagina 41

1-8 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Physical FeaturesPhysical FeaturesPhysic

Pagina 42

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-9 Operating 0 to 2000m (0 to 6,600 ft.) Storage and Transport 0 to 3000m (0 to 10,000

Pagina 43

ii Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) This page intentionally left blan

Pagina 44

1-10 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Summary of DimensionsSummary of Dimension

Pagina 45 - Install the AADvance System

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-11 Base units are moulded from a similar material. Each base unit can be mounted onto stand

Pagina 46

1-12 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Module Locking MechanismModule Locking Me

Pagina 47

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-13 Part No: Digital Input Fuses T9901: No 396/TE5 50mA time lag fuse; UL 248-14, 125 V,T L

Pagina 48

1-14 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) T9100 Processor Base UnitT9100 Processor

Pagina 49

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-15 The processor base unit provides the electrical connections between the T9110 processor

Pagina 50

1-16 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Serial CommunicationsSerial Communication

Pagina 51

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-17 The bus and power connections from the processor base unit enter the backplane at the le

Pagina 52

1-18 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) T9310 Expansion Cable AssemblyT9310 Expan

Pagina 53

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 1-19 Backplane Electrical RatingsBackplane Electrical RatingsBackplane Electrical RatingsBac

Pagina 54

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: iii NoticeNoticeNoticeNotice In no event will Rockwell Automation be responsible or

Pagina 55

1-20 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) This page intentionally left bl

Pagina 56

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-1 This chapter lists important information the reader should consider before starting to bui

Pagina 57

2-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Test EquipmentTest EquipmentTest Equipment

Pagina 58

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-3 Recommended Enclosure for a nonRecommended Enclosure for a nonRecommended Enclosure for a

Pagina 59

2-4 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Free Space Around the ControllerFree Space

Pagina 60

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-5 DIN RDIN RDIN RDIN Rails Fittingails Fittingails Fittingails Fitting You can install th

Pagina 61

2-6 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Base Units, DIN Rail installations and

Pagina 62

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-7 Adding Cable ManagementAdding Cable ManagementAdding Cable ManagementAdding Cable Manageme

Pagina 63

2-8 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller)  PELV (protected extra-low voltage) is a

Pagina 64

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-9 Power Arrangements for Field DevicesPower Arrangements for Field DevicesPower Arrangements

Pagina 65

iv Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Issue RecordIssue RecordIssue RecordIssue R

Pagina 66

2-10 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Total: Note: All figures given are

Pagina 67

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-11 Design Considerations for Electrical GroundingDesign Considerations for Electrical Ground

Pagina 68

2-12 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Specifying the Workstation PCSpecifying

Pagina 69

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 2-13 Design ProvisionsDesign ProvisionsDesign ProvisionsDesign Provisions The design of the

Pagina 70 -  Seconds

2-14 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) In addition, it may be appropriate to mak

Pagina 71

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-1 The system installation defines the steps that will ensure the system is correctly install

Pagina 72

3-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) CAUTION Handling Modules Stored at Extrem

Pagina 73

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-3  Insert the retaining clip on the back of the termination assembly into the slot on the

Pagina 74

3-4 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Allocations of Coding PegsAllocations of

Pagina 75

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-5  Use only finger pressure to manipulate and engage the clips. Do not attempt to use a sc

Pagina 76

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: v Notes and Symbols used in this manual Notes and Symbols used in this manual Notes and

Pagina 77

3-6 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Allocations ofAllocations ofAllocations o

Pagina 78

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-7 Connect the AC Safety Ground ConnectionConnect the AC Safety Ground ConnectionConnect the

Pagina 79

3-8 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) For each power supply connection, do the

Pagina 80

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-9 Power and External Connector Wiring DetailsPower and External Connector Wiring DetailsPowe

Pagina 81

3-10 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) ProceduProceduProceduProcedure to Connect

Pagina 82

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-11 Note: Each processor uses the two serial ports above it on the baseplate. Data is not mi

Pagina 83

3-12 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) RS485 HalfRS485 HalfRS485 HalfRS485 Half

Pagina 84

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-13  Removable media, such as USB storage devices and CDs, should be virus checked before u

Pagina 85

3-14 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Digital Input Field Loop CircuitsDigital

Pagina 86

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-15 The suggested values for R1 and R2 are as follows:  R1 = 15K Ω 1%, 1W (maximum power di

Pagina 87

vi Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) ForewordForewordForewordForeword The AA

Pagina 88

3-16 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Connections to 9802/9803 Isolated Digital

Pagina 89

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-17 Analogue Input Field lAnalogue Input Field lAnalogue Input Field lAnalogue Input Field lo

Pagina 90

3-18 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) 4444----Wire Analogue InputWire Analogue

Pagina 91

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-19 Connections to T9832/T9833 Isolated Analogue Input TA Connections to T9832/T9833 Isolated

Pagina 92

3-20 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Recommended Field Circuit for DigitRecomm

Pagina 93 -  ControlFLASH installs

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-21 Connections to T9851/T9852 Digital Output TA Connections to T9851/T9852 Digital Output TA

Pagina 94

3-22 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) The above circuit is appropriate for devi

Pagina 95

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-23 Note: Apply a minimum tightening torque of 0.5 Nm (0.37 ft lb) to the terminal screws. C

Pagina 96

3-24 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) InstaInstaInstaInstall Modulesll Modulesl

Pagina 97

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-25 3) The module locking screw requires a quarter turn clockwise to lock. Use a broad (9mm)

Pagina 99

3-26 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) (Part No: T9905 Poly-carbonmonofluride L

Pagina 100

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-27 4) To control the time setting, wire variables to the RTC Control points:  RTC Write 

Pagina 101

3-28 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Install Blanking CoversInstall Blanking C

Pagina 102

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-29 Install T9310 Expansion CableInstall T9310 Expansion CableInstall T9310 Expansion CableIn

Pagina 103

3-30 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller)  Secure the socket assembly by insertin

Pagina 104

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-31  Tighten the screws with a 2.5mm Allen key.  Install the cable to the plug assembly a

Pagina 105

3-32 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Fault Reporting Reference InformationF

Pagina 106

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-33 GREEN Module is online and providing data to/receiving data from application AMBER Mo

Pagina 107

3-34 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) and indicates that the module has no hard

Pagina 108

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 3-35 Force Provides an indication that variables are being locked/forced by the application.

Pagina 109

viii Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) ContentsContentsContentsContents Cha

Pagina 110

3-36 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) This page intentionally left bl

Pagina 111

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-1 This chapter describes a structured approach to the start up of a controller system. When

Pagina 112

4-2 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) System Physical Design CheckSystem Physica

Pagina 113

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-3 Procedure to check Power Distribution IntegrityProcedure to check Power Distribution Integ

Pagina 114

4-4 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Start Up ProcessStart Up ProcessStart Up P

Pagina 115 - Parts List

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-5 Step Task Force Will remain OFF as the Module boots up (10 to 20 seconds) then stays OF

Pagina 116

4-6 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Table 9: Table 9: Table 9: Table 9: Pro

Pagina 117

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-7 Step Task When the Run indicator goes AMBER press the Fault Reset button and the processo

Pagina 118

4-8 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Ready GREEN Run AMBER Channel 1 – 8

Pagina 119 - Glossary of Terms

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-9 8. If the module fails to educate and go on-line replace the module.

Pagina 120

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: ix Chapter 3 Chapter 3 Chapter 3 Chapter 3 Install the AADvance System...

Pagina 121

4-10 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) ControlFLASH Firmware UpgradesControlFLAS

Pagina 122

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-11 The RSLinx Classic Lite software must be installed before you can install the ControlFLAS

Pagina 123

4-12 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) 3) Read and agree to the license and cli

Pagina 124

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-13  ControlFLASH installs. 6) To launch ControlFLASH select the Yes I want to launch

Pagina 125

4-14 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller)  ControlFLASH will launch and you can

Pagina 126

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-15 2) Click Next. 3) Select T9110 from the list. 4) Browse to the device in the RSLi

Pagina 127

4-16 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) 5) Select the firmware revision for th

Pagina 128

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-17 The continue message is displayed: 7) Click Yes to continue with the update  A prog

Pagina 129

4-18 Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: System Build Manual (AADvance Controller) Note: It has not locked up! Wait until t

Pagina 130

Document: 553632 (ICSTT-RM448_EN_P) Issue: 08: 4-19 10) Click OK and another error message is displayed. 11) Click OK then Cancel to Exit

Comentarios a estos manuales