3 UPGRADING FROM A PREVIOUS VERSION
27
• • • • •
3. Edit C:\Program Files\Rockwell Software\Emonitor\odoonline.edi as follows:
[Source]
DataFileConfigFile=C:\Program Files\Rockwell
Software\Emonitor\odonline.ini
DataFileDir=C:\Users\Public\Documents\Rockwell
Software\Emonitor\ud
DataFiles=C:\Users\Public\Documents\Rockwell
Software\Emonitor\ud\*.ulf
[Options]
BackupPathnameOnError=C:\Users\Public\Documents\Rockwell
Software\Emonitor\online\backup\
LogFilePathname=C:\Users\Public\Documents\Rockwell
Software\Emonitor\online\online.log
4. Restart the Scheduler and OLDM_Service services.
a. Click Start > Control Panel > Administrative Tools > Services.
b. Select Services (local) in the left side of the Services window.
c. Select SchedulrSvc in the right side of the Services window.
d. If the SchedulrSvc Status is Started, right-click on SchedulrSvc and select Stop.
e. Right-click on SchedulrSvc and select Start.
f. Select OLDM_Service in the right side of the Services window.
g. If the OLDM_Service Status is Started, right-click on OLDM_Service and select
Stop.
h. Right-click on SchedulrSvc and select Start.