Use with DriveExecutive Software D-5
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
15. Launch DriveExecutive software to access parameters in the 1203-USB
converter, the connected drive, and any connected peripherals.
16. From the Drive menu, choose Connect to Drive to display the Connect
To Drive treeview window.
17. Expand the treeview in the left pane to display the ‘DPI’ icon.
The window should look similar to this example window.
18. Select the DPI icon in the right pane.
19. Click OK.
DriveExecutive will begin updating drive information such as parameter
names, diagnostics, and so forth, and store them in a DriveExecutive
software directory established for this purpose.
20. In the left pane of the DriveExecutive window, click ‘+’ to expand the
treeview.
For this example, click 1203-USB. Then click Linear List to display its
parameters in the right pane.
21. To edit a parameter, double-click it or use the Value column pull-down
menu.