Publication 1203-5.13 February, 2002
D-28 ControlNet Objects: Class Code 0x98 SCANport Pass-Through Warning Object
Class Code 0x98 SCANport
Pass-Through Warning Object
The SCANport Pass-Through Warning Object provides information
on the product’s warning queue.
Class Attributes
Instance Attributes
Attribute ID Access Rule Name Data Type Description
0 Set Write Warning
Command
BYTE Write Warning Command.
1 = Clear Warnings
2 = Clear Warning Queue
3 - Reset Product
1 Set Read Number of
Warning Queue Entries
BYTE
Attribute ID Access Rule Name Data Type Description
0
Get Read Warning Queue
Entry Full/All Info
STRUCT of
Warning Text ARRAY of BYTE 16 character string (no length
information, no terminating null).
Warning Code WORD Fault Code.
Warning Time Stamp STRUCT
BYTE 1/100 Second (0 99).
BYTE Second (0 59).
BYTE Minute (0 59).
BYTE Hour (0 23).
BYTE
Day of Week (0 6).
BYTE Date (1 31).
BYTE Month (1 12).
BYTE
Year (0 99
).
128
Get Warning Code and
Time Stamp
STRUCT of
Warning Code WORD Fault Code.
Warning Time Stamp STRUCT of
BYTE 1/100 Second (0 99).
BYTE Second (0 59).
BYTE Minute (0 59).
BYTE Hour (0 23).
BYTE
Day of Week (0 6).
BYTE Date (1 31).
BYTE Month (1 12).
BYTE
Year (0 99
).
129
Get Read Warning Text
String Only
ARRAY of BYTE 16 character string (no length
information, no terminating null).
Sunday is a value of zero.
Year is an offset from 1990.