Publication 1732E-UM002A-EN-P - March 2010
22 Configure the Module for Your EtherNet/IP Network
installation CD. The module must have DHCP enabled (factory default and
the network address switches set to an illegal value) to use the utility.
To configure your module using the BootP/DHCP utility, perform the
following steps:
1. Run the BootP/DHCP software.
The BOOTP/DHCP Request History dialog appears showing the
hardware addresses of devices issuing BootP/DHCP requests.
2. Double-click the hardware address of the device you want to configure.
The New Entry dialog appears showing the device’s Ethernet
Address (MAC).
3. Enter the IP Address you want to assign to the device and click OK.