20 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Thermocouple and RTD Input Modules
Publication 1732E-IN005B-EN-E - September 2012
Common mode
rejection rate
120 dB @ 50/60 Hz
Normal mode rejection
rate
100 dB @ 50/60 Hz
Sample Rate Filters
(1)
50 Hz
60 Hz
250 Hz
500 Hz
(1)
Sample Rate/Notch Filter Frequency, selectable per channel.
Input Specifications – 1732E-IR4IM12R
Attributes Value
Number of inputs 4, isolated
Resolution, min 16 bits
Data format 16-bit sign magnitude
Sensors supported 100…200 =0.00385/0.003916 Pt RTD
100/120 Ni RTD
10 Cu =0.00427 RTD
Sensor Types 100
Pt 385
200
Pt 385
100
Pt 3916
200
Pt 3916
10
Cu 427
120
Ni 672
100
Ni 618
120
Ni 618
Input Specifications – 1732E-IT4IM12R
Attributes Value