62 Rockwell Automation Publication 1769-UM012B-EN-P - January 2014
Chapter 2 Configure the 1769-ASCII Module
Programming Example:
MicroLogix 1500 Controller
This MicroLogix example demonstrates how the 1769-ASCII module's channel
0 collects a line of input from the HyperTerminal and echoes that line to you.
To make sure your 1769-ASCII module is functioning properly, follow these
instructions.
1. Open the RSLogix 500 software.
2. Create a project.
In this example, the name of the project is Micro1500_Quickstart_001.
3. In the project space, double-click I/O Configuration.
4. Select the slot number.
In this example, the 1769-ASCII module is in slot 1.
5. From the list, select Other: Requires I/O Card Type ID.
6. When the I/O module properties appear, enter the following information.
7. Click OK.
8. Click Adv. Config.
Assembly Instance Size
Input 101 108
Output 100 108
Configuration 102 31