Publication 1769-RM016A-EN-P - July 2006
Module Diagnostics and Troubleshooting 63
Error Type Hex
Equivalent
(2)
Module
Error Code
Extended Error
Information
Code
Error Description
Binary Binary
X409 010 0 0000 1001
Invalid Operand_B, OUT 0
(4)
X40A 010 0 0000 1010
Invalid Operand_B, OUT 1
(4)
X40B 010 0 0000 1011
Invalid Operand_B, OUT 2
(4)
X40C 010 0 0000 1100
Invalid Operand_B, OUT 3
(4)
X40D 010 0 0000 1101
Invalid Operand_C OUT 0
(4)
X40E 010 0 0000 1110
Invalid Operand_C, OUT 1
(4)
X40F 010 0 0000 1111
Invalid Operand_C, OUT 2
(4)
X410 010 0 0001 0000
Invalid Operand_C, OUT 3
(4)
X411 010 0 0001 0001
Invalid Boolean expression, OUT 0
(5)
X412 010 0 0001 0010
Invalid Boolean expression, OUT 1
(5)
X413 010 0 0001 0011
Invalid Boolean expression, OUT 2
(5)
X414 010 0 0001 0100
Invalid Boolean expression, OUT 3
(5)
X415 010 0 0001 0101
Invalid Output Delay value, OUT 0
(6)
X416 010 0 0001 0110
Invalid Output Delay value, OUT 1
(6)
X417 010 0 0001 0111
Invalid Output Delay value, OUT 2
(6)
X418 010 0 0001 1000
Invalid Output Delay value, OUT 3
(6)
X419 010 0 0001 1001
Invalid Output Duration value, OUT 0
(7)
X41A 010 0 0001 1010
Invalid Output Duration value, OUT 1
(7)
X41B 010 0 0001 1011
Invalid Output Duration value, OUT 2
(7)
X41C 010 0 0001 1100
Invalid Output Duration value, OUT 3
(7)
(1)
X represents the Don't Care digit.
(2)
X represents the Don't Care digit.
(3)
EI_O bit set (1) while DB bit set (1).
(4)
Operand value not between 0 and 32 decimal.
(5)
Invalid Boolean expression configuration. Refer to Boolean Expression Configuration Restrictions on page 15, for valid Boolean expression configurations.
(6)
Output Delay value less than 0 or greater than 1000 decimal.
(7)
Output Duration value less than 0 or greater than 1000 decimal.