90 Configure Modules in a Remote DeviceNet System with a 1769-ADN DeviceNet Adapter
5. Under the Configuration Settings tab, you can select the parameter that
you want to configure and initiate an action using the toolbar.
6. Set each parameter's current value to match the desired
1769-BOOLEAN module configuration settings.
7. Click OK or Cancel to exit this screen and return to the Configuration
screen.
The revision number for the 1769-BOOLEAN module is one. With this
setting, you may leave the electronic keying to Exact Match. It is not
recommended to disable keying, but if you are not sure of the exact
revision of your module, selecting Compatible Module allows your
system to operate, while still requiring a 1769-BOOLEAN module in
slot 1.