13–17PLC Addressing
Publication
17706.5.16 - October 1996
PLC5 Floating Point
PLC-5 type reads and type writes use the IEEE floating point.
(This is the default for PLC-5 processors.) This means data is
returned:
low word then high word
low byte then high byte
Example:
PLC5
type read
2.0 =
FF
FF FF
BF
1000.00 = 00 00 7A 44
low high
low
high
low word
high word
exponent
MSB  mantissa
middle MSB  mantissa
LSB  mantissa
Example:
PLC5
word range read
1000.00 =
7A
44 00
00
2.0 =
FF
BF FF
FF
3.0 =
40
C0 00
00
low high
low
high
low word
high word