Calculating the Distance to a Short
1788-UM002A-US-P – April 2000
Table 13. DeviceNet and DH+/RIO Cable Resistances
Cable Type
Data Pair
(H, L)
Power Pair
(+,-) Shield
DeviceNet
Thick
0.0069 /ft
0.0226 /m
0.0032 /ft
0.0105 /m
0.00175 /ft
0.00575 /m
DeviceNet
Thin
0.028 /ft
0.0918 /m
0.01617 /ft
0.053 /m
0.0032 /ft
0.0105 /m
DeviceNet
KwikLink
0.00404 /ft
0.01325 /m
0.00404 /ft
0.01325 /m
NA
DH+/RIO 0.00944 /ft
0.031 /m
NA 0.0041/ft
0.0135 /m
Table 14. ControlNet Cable Resistances
Cable Type Center
Conductor
Shield
ControlNet RG6
0.028 /ft
0.0918 /m
0.0036 /ft
0.0118 /m
ControlNet RG6F
0.0099 /ft
0.0325 /m
0.0029 /ft
0.0095 /m
ControlNet DS3/4
0.0255 /ft
0.0836 /m
0.0032 /ft
0.0105 /m