Rockwell-automation 1794-IJ2XT FLEX I/O Frequency Input Modules User M Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1794-IJ2XT FLEX I/O Frequency Input Modules User M. Rockwell Automation 1794-IJ2XT FLEX I/O Frequency Input Modules User Manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 87
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
FLEX I/O Frequency Input Module
Catalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XT
User Manual
Vista de pagina 0
1 2 3 4 5 6 ... 86 87

Indice de contenidos

Pagina 1 - User Manual

FLEX I/O Frequency Input ModuleCatalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XTUser Manual

Pagina 2 - Important User Information

Publication 1794-6.5.11 - September 2011xii PrefaceCommon Techniques Used in this ManualThe following conventions are used throughout this manu

Pagina 3 - Information

1 Publication 1794-6.5.11 - September 2011Chapter 1Overview of the Frequency Input ModuleOverviewThis chapter provides a description of the applicatio

Pagina 4

Publication 1794-6.5.11 - September 20112 Overview of the Frequency Input Module• I/O module – contains the bus interface and circuitry needed

Pagina 5 - Table of Contents

Publication 1794-6.5.11 - September 2011Overview of the Frequency Input Module 3The primary use of the module is accurate, high-speed frequency

Pagina 6

Publication 1794-6.5.11 - September 20114 Overview of the Frequency Input ModuleTypical Communication between a FLEX I/O Module and an AdapterF

Pagina 7 - About the Vocabulary

Publication 1794-6.5.11 - September 2011Overview of the Frequency Input Module 5A broader view of how the FLEX I/O module interfaces with the d

Pagina 8 - Related Documentation

Publication 1794-6.5.11 - September 20116 Overview of the Frequency Input ModuleInput CapabilitiesThe frequency module has 2 input channels (mo

Pagina 9 - Preface xi

Publication 1794-6.5.11 - September 2011Overview of the Frequency Input Module 7Selecting the Modes of OperationYou configure the frequency inp

Pagina 10 - Common Techniques Used

Publication 1794-6.5.11 - September 20118 Overview of the Frequency Input Moduleprocessor to do other tasks and helps increase the overall thro

Pagina 11 - The FLEX System

Publication 1794-6.5.11 - September 2011Overview of the Frequency Input Module 9Normal Mode Frequency Determination, at Least Two Pulses in Sam

Pagina 12 - Input Module

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Pagina 13 - Logix Control System

Publication 1794-6.5.11 - September 201110 Overview of the Frequency Input ModuleTermination on Number of PulsesThe normal mode is designed to

Pagina 14 - 1794-IJ2

Publication 1794-6.5.11 - September 2011Overview of the Frequency Input Module 11Direction DetectionDirection detection is accomplished by usin

Pagina 15 - Typical Applications

Publication 1794-6.5.11 - September 201112 Overview of the Frequency Input ModuleDirection Detection – Principle of Operation Chapter Summar

Pagina 16 - Input Capabilities

13 Publication 1794-6.5.11 - September 2011Chapter 2Install Your FLEX I/O Frequency Input ModuleOverviewThis chapter provides you with pre-installatio

Pagina 17 - Output Capabilities

Publication 1794-6.5.11 - September 201114 Install Your FLEX I/O Frequency Input Module The frequency input module requires 30 mA at 5V DC fro

Pagina 18 - Calculated

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 152. Check to make sure that the 16 pins in the male conne

Pagina 19 - Sampling Time Extended

Publication 1794-6.5.11 - September 201116 Install Your FLEX I/O Frequency Input Module6. Press down on the terminal base unit to lock the term

Pagina 20 - Missing Pulse Multiplier

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 17• installing the terminal base units and securing them t

Pagina 21 - Direction Detection

Publication 1794-6.5.11 - September 201118 Install Your FLEX I/O Frequency Input Module2. Drill the necessary holes for the #6 self-tapping mou

Pagina 22 - Chapter Summary

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 19 2. Make certain the FlexBus connector (1) is pushed al

Pagina 23 - Power Requirements

iii Publication 1794-6.5.11 - September 2011Summary of ChangesThis manual contains new and updated information. Changes throughout this revision are m

Pagina 24 - Install the Module

Publication 1794-6.5.11 - September 201120 Install Your FLEX I/O Frequency Input Module Wiring InformationThis section provides essential wirin

Pagina 25

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 21 Wire the Terminal Base UnitsWiring the FLEX I/O Freque

Pagina 26 - Mount on a Panel or Wall

Publication 1794-6.5.11 - September 201122 Install Your FLEX I/O Frequency Input ModuleConnecting Wiring Using a 1794-TB3G, 1794-TB3GK or 1794-

Pagina 27 - Description Description

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 23Wiring Connections for the Frequency Input Module Chan

Pagina 28 - IMPORTANT

Publication 1794-6.5.11 - September 201124 Install Your FLEX I/O Frequency Input Module Resolution and Accuracy1 Hz or 0.1 Hz (depending on

Pagina 29

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 25Resolution % is defined as: Accuracy % is defined as:

Pagina 30

Publication 1794-6.5.11 - September 201126 Install Your FLEX I/O Frequency Input Module5 Reserved Diagnostic StatusChannel 0Reserved Diagnostic

Pagina 31 - 34...51

Publication 1794-6.5.11 - September 2011Install Your FLEX I/O Frequency Input Module 27Examples of Wiring to a 1794-TB3G Terminal Base UnitChap

Pagina 32 - 1794-TB3GS Terminal Base Unit

Publication 1794-6.5.11 - September 201128 Install Your FLEX I/O Frequency Input ModuleNotes:

Pagina 33 - ATTENTION

29 Publication 1794-6.5.11 - September 2011Chapter 3Configure Your FLEX I/O Module with RSLogix 5000 SoftwareOverviewThis chapter describes how to con

Pagina 34 - Resolution and Accuracy

Publication 1794-6.5.11 - September 2011iv Summary of ChangesNotes:

Pagina 35 - Accuracy % is defined as:

Publication 1794-6.5.11 - September 201130 Configure Your FLEX I/O Module with RSLogix 5000 Software1. Select New Module for the I/O Configurat

Pagina 36

Publication 1794-6.5.11 - September 2011Configure Your FLEX I/O Module with RSLogix 5000 Software 31Complete the following fields and click OK.

Pagina 37

Publication 1794-6.5.11 - September 201132 Configure Your FLEX I/O Module with RSLogix 5000 Software6. On the Configuration tab, specify the fo

Pagina 38

Publication 1794-6.5.11 - September 2011Configure Your FLEX I/O Module with RSLogix 5000 Software 33 You should now see the 1794-IJ2 module add

Pagina 39 - RSLogix 5000 Software

Publication 1794-6.5.11 - September 201134 Configure Your FLEX I/O Module with RSLogix 5000 SoftwareNotes:

Pagina 40 - Select New Module

35 Publication 1794-6.5.11 - September 2011Chapter 4Read and Write Configuration Maps for the FLEX I/O ModuleOverviewThis chapter describes how to con

Pagina 41

Publication 1794-6.5.11 - September 201136 Read and Write Configuration Maps for the FLEX I/O ModuleMap Data for the ModuleThe following read a

Pagina 42

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 37 4 R R DirectionCh 0GS Ch 0F/A Ch 0W

Pagina 43

Publication 1794-6.5.11 - September 201138 Read and Write Configuration Maps for the FLEX I/O ModuleWord 4 Bits 00 Missing Pulse Alarm (channel

Pagina 44

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 39Word 5 Bits 00…03 Diagnostic Status – indic

Pagina 45 - FLEX I/O Module

v Publication 1794-6.5.11 - September 2011Table of ContentsSummary of ChangesNew and Updated Information. . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - Map Data for the Module

Publication 1794-6.5.11 - September 201140 Read and Write Configuration Maps for the FLEX I/O Module5 Frequency Scaling Divisor 0…255 Ch 1 Freq

Pagina 47 -

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 41Word 0 (con’t.)Bits 05 Frequency range bits

Pagina 48

Publication 1794-6.5.11 - September 201142 Read and Write Configuration Maps for the FLEX I/O ModuleBit 13 (15) Frequency range bits (channel 0

Pagina 49

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 43Word 3 Bits 00…01 Wire-Off/Missing Pulse fa

Pagina 50 - Word Bit

Publication 1794-6.5.11 - September 201144 Read and Write Configuration Maps for the FLEX I/O ModuleWord 3 Bit 07 Minimum Frequency Sampling Ti

Pagina 51

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 45Word 4 Bits 00…15 (00…17)Maximum frequency

Pagina 52

Publication 1794-6.5.11 - September 201146 Read and Write Configuration Maps for the FLEX I/O ModuleWord 6 Bits 00…01 Wire-Off/Missing Pulse fa

Pagina 53

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 47Word 6 Bit 07 Initiate Startup Select (chan

Pagina 54

Publication 1794-6.5.11 - September 201148 Read and Write Configuration Maps for the FLEX I/O ModuleWord 6 Bit 13 (15) Invert Select – Gate Inp

Pagina 55

Publication 1794-6.5.11 - September 2011Read and Write Configuration Maps for the FLEX I/O Module 49Chapter SummaryThis chapter provided the us

Pagina 56

Publication 1794-6.5.11 - September 2011vi Table of ContentsChapter 3Configure Your FLEX I/O Module with RSLogix 5000 SoftwareOverview . . . .

Pagina 57

Publication 1794-6.5.11 - September 201150 Read and Write Configuration Maps for the FLEX I/O ModuleNotes:

Pagina 58

35 Publication 1794-6.5.11 - September 2011Chapter 5Troubleshoot the ModuleOverviewThis chapter provides a description of the different status indicat

Pagina 59

Publication 1794-6.5.11 - September 201136 Troubleshoot the ModuleWhen an output indicator is yellow, the logic is driving an output alarm On.

Pagina 60

Publication 1794-6.5.11 - September 2011Troubleshoot the Module 37Diagnostic Bits in Word 5 of the BTR File Chapter SummaryThis chapter expla

Pagina 61 - Troubleshoot the Module

Publication 1794-6.5.11 - September 201138 Troubleshoot the ModuleNotes:

Pagina 62 - Diagnostics

55 Publication 1794-6.5.11 - September 2011Appendix ASpecificationsWhat This Appendix ContainsThis appendix contains the frequency accuracy and genera

Pagina 63

Publication 1794-6.5.11 - September 201156 Specifications Output Specifications(1)(1)Meets IEC 1A 24V DC output specifications.Attribute Value

Pagina 64

Publication 1794-6.5.11 - September 2011Specifications 57 Power dissipation, max 4.6W @ 31.2V DCThermal dissipation, max 15.6 BTU/hr @ 31.2V D

Pagina 65 - Specifications

Publication 1794-6.5.11 - September 201158 SpecificationsESD immunity IEC 61000-4-2:4 kV contact discharges – 1794-IJ2 and 1794-IJ2K6 kV contac

Pagina 66 - 56 Specifications

59 Publication 1794-6.5.11 - September 2011Appendix BElectronic Data Sheet (EDS) FilesOverviewEDS provides the definition for a device's configur

Pagina 67 - Specifications 57

ix Publication 1794-6.5.11 - September 2011PrefaceRead this preface to familiarize yourself with the rest of the manual. It provides information conce

Pagina 68 - 58 Specifications

Publication 1794-6.5.11 - September 201160 Electronic Data Sheet (EDS) FilesTo acquire EDS files for Rockwell Automation and Allen-Bradley devi

Pagina 69 - Appendix

61 Publication 1794-6.5.11 - September 2011Appendix CSchematicsWhat This Appendix ContainsUse this appendix to understand the internal logic of the FL

Pagina 70 - EDS Installation

Publication 1794-6.5.11 - September 201162 SchematicsOutput CircuitsThe Frequency Input module output logic consists of digital outputs.Digital

Pagina 71 - Schematics

Publication 1794-6.5.11 - September 2011Schematics 63.DC to DC Converters – 24V DC Power SuppliesThe module provides two 24V (±10%) power sourc

Pagina 72 - Output Circuits

Publication 1794-6.5.11 - September 201164 SchematicsNotes:

Pagina 73

65 Publication 1794-6.5.11 - September 2011Appendix DProgram Your Module with PLC ProcessorsOverviewThis Appendix serves as a reference to users of th

Pagina 74 - 64 Schematics

Publication 1794-6.5.11 - September 201166 Program Your Module with PLC ProcessorsPLC-2 Family ProcessorThe 1794 Frequency I/O module is not re

Pagina 75 - Instructions

Publication 1794-6.5.11 - September 2011Program Your Module with PLC Processors 67PLC-5 Family ProcessorBlock transfer instructions with the PL

Pagina 76 - PLC-3 Family Processor

Publication 1794-6.5.11 - September 201168 Program Your Module with PLC ProcessorsPLC-5/250 Family ProcessorBlock transfer instructions with th

Pagina 77 - PLC-5 Family Processor

Publication 1794-6.5.11 - September 2011Program Your Module with PLC Processors 69ENBTRBLOCK TRANSFER READRackGroupSlotControl Block1410BR141:0

Pagina 78 - PLC-5/250 Family Processor

Publication 1794-6.5.11 - September 2011x PrefaceRelated DocumentationThe following documents contain additional information concerning Rockwel

Pagina 79

Publication 1794-6.5.11 - September 201170 Program Your Module with PLC ProcessorsNotes:

Pagina 80

Publication 1794-6.5.12 - September 2011IndexNumerics1756-ENBT 291794-ACN15 41794-ACNR1 41794-ACNR15K 41794-ADN 41794-AENT 41794-APB 41794-APBDPV1 417

Pagina 81 - Numerics

Publication 1794-6.5.12 - September 201172 Indexcalibrationfailure 39, 53chassis 13, 21, 22combination type 21communication 3, 4, 40, 41, 63, 6

Pagina 82 - 72 Index

Publication 1794-6.5.12 - September 2011Index 73minimum 46minimum sample time 32, 33, 41, 47overange 39parameters 8percentage full scale 7range

Pagina 83 - Index 73

Publication 1794-6.5.12 - September 201174 IndexMSG instructions 5Ooil and gas 5operationmode 7non-normal 39normal 39, 53unintended 14output 52

Pagina 84 - 74 Index

Publication 1794-6.5.12 - September 2011Index 75indicator 52Ttags 5terminal base 1, 13, 14, 15, 17, 19grounding 22installation 14mount 14replac

Pagina 85 - Index 75

Publication 1794-6.5.12 - September 201176 IndexNotes:

Pagina 86 - 76 Index

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Publication 1794-6.5.11 - Septembe

Pagina 87 - Documentation Feedback

Publication 1794-6.5.11 - September 2011Preface xiFLEX I/O 4 Isolated Input Module Installation Instructions, publication 1794-IN038 x xxxx

Comentarios a estos manuales