Rockwell-automation 1791-XXXX Discrete I/O AC and DC Block I/O Input a Manual de usuario Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 98
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
Configuring Your Block I/O for PLC
Family Programmable Controllers
Chapter 4
4-12
Figure 4.15
Input/Output
Image Table Usage Example for One I/O Group for Series B
32point Output Modules (cat. no. 17910A32, 0B32) Complemented by
Series B 32point Input Modules (cat. no. 179132A0, 32B0)
110
111
010
011
Starting
I/O
Group
0
Block Data
Block Data
Type
of I/O
I/O Rack Number
I/O Group Number
I/O Bit
01000
1 = Input
0 = Output
PLC2 Example
10838I
Type
of I/O
I/O Rack Number
I/O Group Number
I/O Bit
O1000
I = Input
O = Output
PLC5 Family Example
11 10
7654321
016 15 14 13 12 11 1017
7654321016 15 14 13 12 11 1017
11 10
7654321
016 15 14 13 12 11 1017
7654321016 15 14 13 12 11 1017
Input
Image
(used by Input Module)
Output Image
(used by output module)
Figure 4.16
I/O
Image T
able for One Assigned Rack Number with Series B 32point
Modules and Series B 16point Modules Complemented by each other
Output Image
Input Image
0
1
2
3
4
5
6
7
017
0
1
2
3
4
5
6
7
710
1 I/O Rack
17910B16
17910B16
17910B32
17910B32
PLC
SLC
07815
SLC
07815
017 710
PLC
179132A0
179132B0
179116B0
179116A0
1/4 Rack
1/4 Rack 1/4 Rack 1/4 Rack
Reserved
Reserved
Reserved
Reserved
Vista de pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 97 98

Comentarios a estos manuales

Sin comentarios