Rockwell-automation 1794-IF8IH FLEX I/O 8 Isolated Input HART Analog M Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1794-IF8IH FLEX I/O 8 Isolated Input HART Analog M. Rockwell Automation 1794-IF8IH FLEX I/O 8 Isolated Input HART Analog Module Installation Instructions User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Installation Instructions
FLEX I/O Isolated Input HART Analog Module
Catalog Number 1794-IF8IH
Topic Page
Important User Information 2
Environment and Enclosure 3
Preventing Electrostatic Discharge 4
North American Hazardous Location Approval 5
Install the Module 7
Wire the Module 8
Ground the Module 10
Module Wiring 11
Cyclic HART Input Data 19
Status Indicator 23
Specifications 23
IMPORTANT
This module can only be used with 1794-ACN(R)15 with version 5.1 (or
greater) firmware, or 1794-AENT with version 4.2 (or greater) firmware. The
1794-AENT currently ships with version 4.1 firmware.
For more information about using this module with 1794-ACN(R)15 with
version 5.1 (or greater) firmware, see 1794-RN071
.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Installation Instructions

Installation InstructionsFLEX I/O Isolated Input HART Analog ModuleCatalog Number 1794-IF8IH Topic PageImportant User Information 2Environment and Enc

Pagina 2 - Important User Information

10 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Ground the ModuleAll I/O wiring must use shielded wire. Shie

Pagina 3

FLEX I/O Isolated Input HART Analog Module 11Publication 1794-IN115C-EN-P - April 2009Module Wiring 0

Pagina 4

12 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Wire ConnectionsChannel Signal Ty peLabel MarkingsCatalog N

Pagina 5

FLEX I/O Isolated Input HART Analog Module 13Publication 1794-IN115C-EN-P - April 2009Input Map Word Bit15141312111098765432100 Channel 0 Input Da

Pagina 6

14 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Configuration MapWord Bit15141312111098765432100RRF7F6F5F4BO

Pagina 7 - Install the Module

FLEX I/O Isolated Input HART Analog Module 15Publication 1794-IN115C-EN-P - April 200929…32Words 9…12 for channel 533…36Words 9…12 for channel 637

Pagina 8 - Wire the Module

16 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Cn HART CMD 3 Disable 0: HART CMD 3 communications enabled1:

Pagina 9 - ATTENTION

FLEX I/O Isolated Input HART Analog Module 17Publication 1794-IN115C-EN-P - April 20094.17 Hz 5 101Not applicable 6 1 1 0Not applicable 7 1 1 1HAR

Pagina 10 - Ground the Module

18 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Channel Data FormatsFormat(1)Bits Format NameSignal Range Us

Pagina 11 - Publication

FLEX I/O Isolated Input HART Analog Module 19Publication 1794-IN115C-EN-P - April 2009Cyclic HART Input DataThe HART input data holds the primary

Pagina 12 - Wire Connections

2 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Important User InformationSolid state equipment has operation

Pagina 13 - Input Map

20 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009HART Input DataWord Bit15141312111098765432100 Reserved CH7C

Pagina 14 - Configuration Map

FLEX I/O Isolated Input HART Analog Module 21Publication 1794-IN115C-EN-P - April 200950…61Words 2…13 for channel 462…73Words 2…13 for channel 574

Pagina 15

22 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009HART Input Data descriptionsCHn: HART CMD 3 Communication St

Pagina 16 - Channel Digital Filter

FLEX I/O Isolated Input HART Analog Module 23Publication 1794-IN115C-EN-P - April 2009Status IndicatorThe OK status indicator is bicolor, red, and

Pagina 17 - HART Current Ratio

24 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Normal mode rejection ratio - current terminal>70 dB @ 50

Pagina 18 - Channel Data Formats

FLEX I/O Isolated Input HART Analog Module 25Publication 1794-IN115C-EN-P - April 2009Wiring category(3)2 on signal ports 3 on power portsWire typ

Pagina 19 - Cyclic HART Input Data

26 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Environmental Attribute ValueTemperature, operating IEC 6006

Pagina 20 - HART Input Data

FLEX I/O Isolated Input HART Analog Module 27Publication 1794-IN115C-EN-P - April 2009EFT/B Immunity IEC 61000-4-4: ±3 kV at 5 kHz on signal ports

Pagina 21

Publication 1794-IN115C-EN-P - April 2009 PN-44688Supersedes Publication 1794-IN115B-EN-P - October 2008 Copyright © 2009 Rockwell Automation, Inc. Al

Pagina 22 - HART Input Data descriptions

FLEX I/O Isolated Input HART Analog Module 3Publication 1794-IN115C-EN-P - April 2009Environment and Enclosure ATTENTIONThis equipment is

Pagina 23 - Specifications

4 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009Preventing Electrostatic Discharge ATTENTIONThis pro

Pagina 24

FLEX I/O Isolated Input HART Analog Module 5Publication 1794-IN115C-EN-P - April 2009North American Hazardous Location Approval The following in

Pagina 25

6 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 2009European Hazardous Location Approval European Zone

Pagina 26 - Environmental

FLEX I/O Isolated Input HART Analog Module 7Publication 1794-IN115C-EN-P - April 2009Install the ModuleRead this for information about how to inst

Pagina 27 - Certifications

8 FLEX I/O Isolated Input HART Analog Module Publication 1794-IN115C-EN-P - April 20093. Make sure the pins on the bottom of the module are straigh

Pagina 28 - Installation Assistance

FLEX I/O Isolated Input HART Analog Module 9Publication 1794-IN115C-EN-P - April 20093. Connect the +V DC power lead to terminal 34 on the 34…51 r

Comentarios a estos manuales

Sin comentarios