Publication 2711P-UM002B-EN-P - March 2007
54 Compiling, Downloading, and Running Application
Download Application to
Terminal
Typically, downloading an application to a terminal is accomplished
using the RSLinx Enterprise File Transfer Utility. You can download an
application using a Compact Flash card, a serial connection, or an
Ethernet connection. Refer to the RSView Machine Edition User
Manual (ViewME-UM003).
1. From the menu bar, select Tools>Transfer Utility…
2. On the Download tab, click the button.
3. Select the .mer file and click
You should see the following dialog.
4. Select the target PanelView Plus using the Ethernet browsing
capability of RSLinx Enterprise. Right-click on the Ethernet,
AB_ETH-1 driver and select Start Browsing.
5. Highlight your PanelView Plus or PanelView Plus CE terminal
and click