38 PanelView Plus CE-Specific Extensions to the WinCE API
dwTimeout
Timeout in milliseconds. This parameter must be one of the following
values:
dwTimeoutAction
Determines what action is taken when a timeout occurs. This
parameter must be one of the following values:
Software Watchdog Timeout Values
Value Description
WATCHDOG_KICK (Value = 0) Tags (restarts) the watchdog indicating that the
process is active.
50 – 5000 milliseconds The watchdog timeout in milliseconds. Once the
watchdog is activated, the caller must tag the
watchdog monitor before a timeout occurs.
WATCHDOG_DISABLE
(Value = MAXDWORD)
Stops the instance of the software watchdog that
corresponds to the Watchdog Tag ID.
Software Watchdog Timeout Actions
Value Description
WATCHDOG_SYSRESET Reset the system.
WATCHDOG_APP_STOP Stop the process. The system will continue to operate.
WATCHDOG_TIMEOUT_PROMPT This is an attribute of the actions:
WATCHDOG_SYSRESET, or WATCHDOG_APP_STOP.
When OR’d with one of these flags, a prompt will be
displayed on the user screen. The prompt must be
acknowledged before the action proceeds.