74 PanelView Plus CE-Specific Extensions to the WinCE API
Members
nIndex
The record index.
nType
Event Type
LocalTime
Time and Date Stamp
szDescription
A text string that describes the Event.
Log New Event
This function writes a new Event to the Event Log.
void LogNew Event(LPCTSTR szEventDescription, int
nEventType);
Parameters:
szEventDescription
A pointer to a text string that describes the Event.
nEventType
This parameter must be one of the values in Table .
Event Types
Value Description
EVENT_UNUSED Event record is empty; i.e. unused.
EVENT_WARNING Event is a warning condition; e.g. low battery.
EVENT_ERROR Event is an error condition; CPU Over-temperature.
EVENT_INFO Event is information only; e.g. Last Boot Reason