42 PanelView Plus CE-Specific Extensions to the WinCE API
System Parameters
The system maintains information about the system. An application
program can use the functions described here to read or write the
system parameters.
System Parameters and Data Types
The following table enumerates currently defined parameters that can
be accessed with these functions. The table shows the data type,
minimum size, and whether set, get, or both actions are allowed. This
table may be expanded in the future to add new parameter types
without adding new functions.
System Parameters
Parameter Macro Identifier Get or
Set
Type Size
(Bytes)
Portability
RAM Memory Size RM_PARAMETER_PHYSICAL_MEMORY_SIZE Get DWORD 4 RAC6182
PanelView Plus CE
CPU Speed RM_PARAMETER_CPU_SPEED_HZ Get DWORD 4 RAC6182
PanelView Plus CE
Windows CE Version RM_PARAMETER_WINDOWS_CE_VERSION Get WCHAR[80] 80 X 2 RAC6182
PanelView Plus CE
Win CE Firmware Build
Version
RM_PARAMETER_OS_FIRMWARE_VERSION Get WCHAR[80] 80 X 2 RAC6182
PanelView Plus CE
Firmware Version RM_PARAMETER_MICROCONTROLLER_
FIRMWARE_VERSION
Get WCHAR[80] 80 X 2 RAC6182
PanelView Plus CE
Enables Serial Debug
Messages on
Startup/Boot
RM_PARAMETER_ENABLE_SERIAL_DEBUG_
ON_BOOT
Both BOOL 4 RAC6182
PanelView Plus CE
LCD Brightness RM_PARAMETER_LCD_BRIGHTNESS Both DWORD 4 RAC6182
PanelView Plus CE
MAC ID of on board
Ethernet
RM_PARAMETER_ON_BOARD_
ETHERNET_MAC_ADDRESS
Get UCHAR[6] 6 RAC6182
PanelView Plus CE
Remove mouse cursor
from display
RM_PARAMETER_CURSOR_ENABLED Both BOOL 4 RAC6182
PanelView Plus CE
Enables Serial Debug
Messages on
Startup/Boot
RM_PARAMETER_ENABLE_SERIAL_DEBUG Both BOOL 4 RAC6182
PanelView Plus CE
Converts virtual to
physical address
RM_PARAMETER_PHYSICAL_ADDRESS Get PUCHAR 4 RAC6182
PanelView Plus CE
Version of BBC RM_PARAMETER_BBC_VERSION Get DWORD 4 PanelView Plus CE
Version of EBC RM_PARAMETER_EBC_VERSION Get DWORD 4 PanelView Plus CE
Display ON Time RM_PARAMETER_DISPLAY_ON_TIME Get DWORD 4 PanelView Plus CE
Terminal ON Time RM_PARAMETER_TERMINAL_ON_TIME Get DWORD 4 PanelView Plus CE
Long POST mask RM_PARAMETER_POST_SELECTIONS Both UCHAR[16] 16 PanelView Plus CE
Disable User
Interfaces
RM_PARAMETER_DISABLE_USER_INPUT Set BOOL 4 PanelView Plus CE