Chapter 8
Defining Strings for Serial Ports and Viewports
8 14
W1(08) 12340000
Examples: Assume formula 1 result = 123.4
This code
transmits (or displays) this field:
F1(08) 0123.400
F1(08) 123.4000
(x.d) The x indicates the field width, while the d value specifies the
maximum number of decimal places to be present in the field. Note that the
d value is only effective if decimal places are actually part of the tool result.
Also, if the specified field width is not large enough to include the entire
result whole number component and all of the decimal component the
result is truncated from the right. A d value of 0 can be used this specifies
that no decimal places (or decimal points) are used.
Examples: Assume formula 1 result = 1234.56
This code
transmits (or displays) this field:
F1(7.2) 1234.56
F1(8.1) _ _ 1234.5
F1(8.1) 1234.5 _ _
F1(08.1) 001234.5
F1(08.1) 1234.500
F1(6.3) 1234.5
F1(5.0) _ 1234 (with .0 used, the decimal point is suppressed)
Default Formats:
If you do not specify a format for a data or index field, the default format is
used. The default formats are:
(9) for all fields, other than index fields, with no decimal places. The
field width is 9 characters; the contents of the field are right justified.
(9.3) for fields with decimal places. The field width is 9 characters
including five places left of the decimal point, and three decimal places.