Chapter 8
Defining Strings for Serial Ports and Viewports
8 43
Format codes are added to each data code. The format code (7.3) is
added to the data code S#.3 (the mean), setting the width of the
displayed data field to seven places, and limiting the decimal portion of
the field to three places. The format code (7.4) is added to the data
code S#.4 (the standard deviation), setting the field width to seven
places, and limiting the decimal portion of the field to four places.
Literal text (in this case, spaces enclosed in quotes) is used to provide
spacing between the two data fields.
The N (newline) character causes subsequent string text to be displayed
directly below the previous text. In this case, used with the Repeat
String feature (discussed below), the N character is used to display the
repeated string in a column, rather than across the viewport from left to
right, which is not desirable in this case.
Using the Repeat String and # (Index) Character with Statistics Codes
Recall that the Repeat String feature allows you to repeatedly display a
string. This is accomplished through the use of an index number, which is
incremented through a range of values you define this range using the
Repeat String menu.
You can use the # (index) character in the string; when the # is placed in the
string text as part of a data code, the # is replaced in the data code with the
current index value.
Remember that we are using the data codes S#.3 for the mean (where # is
the tool type and tool number indicator) and S#.4 for the standard deviation
in the string. In both cases, when the string is repeatedly displayed, the