Rockwell-automation 5720 DriveLogix System Manual de usuario Pagina 121

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 263
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 120
Publication 20D-UM002C-EN-P - November 2003
Communicating with Devices on an EtherNet/IP Link 6-5
7. Enter the IP address or Host Name of your 1788-ENBT module (e.g.,
130.130.130.2, “Pump1”, etc.). Use of the IP address on this screen
informs the controller of the daughtercard’s IP address for processes
such ladder logic and I/O data exchange. You can set the IP address in
any of these ways:
Rockwell BootP Utility
RSLinx software
Third-party BootP server
DHCP network server
For moreinformation on using these tools, see the EtherNet/IP
Communication Daughtercard user manual, publication 1788-UM054.
8. Repeat step 6 for each additional Ethernet module you need to access.
9. When you are done entering the IP addresses, click on Apply.
Vista de pagina 120
1 2 ... 116 117 118 119 120 121 122 123 124 125 126 ... 262 263

Comentarios a estos manuales

Sin comentarios