Rockwell-automation 6012DB PowerFlex Medium Voltage Variable Frequency Manual de usuario Pagina 103

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 102
Rockwell Automation Publication 6000-UM001B-EN-P - October 2014 103
Preventative Maintenance and Component Replacement Chapter 5
G3 Power Supply
1. Loosen, but do not remove, the screws on the top of the G3 Power Supply.
2. Remove the wires.
Figure 40 - Remove G3 Power Supply wires (G1 and G2 Power Supply not shown for clarity)
3. Remove two M3 Tapping screws to remove the unit.
Figure 41 - Remove AC/DC Power Supply
4. Install the new power supply in reverse order of removal.
Loosen screws and remove all wires
M3 Tapping Screw
Vista de pagina 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 137 138

Comentarios a estos manuales

Sin comentarios