6.1.1 Input
P
arameters for the Logical AND Instruction
This table lists the inputs for the AND instruction and the variable type and data
type/range that each input supports.
Parameter
Description V
ariable T
ype Data Type/Range
EN When this input is true, the instruction executes. When this
input is false, the instruction is not executed and ENO is
false.
Connect a Boolean input or output.
In1
In2
Enter two variables or
constants on which you want to per
Ć
form the logical AND.
Note: Any constants entered are displayed in hexadecimal.
D simple
D constant
D element of an array
integer (0ĆFFFF)
double integer
(0ĆFFFFFFFF)
6.1.2 Output
P
arameters for the Logical AND Instruction
This table lists the outputs for the AND instruction and the variable type and data
type/range that each output supports.
Parameter
Description V
ariable T
ype Data/Type Range
ENO Use this output as the input to another instruction for
easily chaining multiple instructions. This output follows
the state of EN unless and error occurs.
Connect a contact, coil, or Boolean input to
another instruction.
Out This output contains the result of the AND operation on
In1 and In2.
D simple
D element of an array
integer (0ĆFFFF)
double integer
(0ĆFFFFFFFF)