10Ć9
10.1.2 Output
P
arameters for the Unary Array Instruction
This table lists the outputs for the AR1 instruction and the variable type and data
type/range that each output supports.
Parameter
Description V
ariable T
ype Data/Type Range
ENO Use this output as the input to another instruction for
easily chaining multiple instructions. This output follows
the state of EN unless an error occurs.
DN This output is true when the instruction has operated on
the last array element or an error was found during the
first scan.
DN is false when EN is false.
Connect a contact, coil or Boolean parameter of
another instruction.
ER This output is set true after the instruction is completed
when an error was encountered during its operation.
This output is set false when EN is false.
Out Enter the name of a variable in which you want to store
the result of the Operation. The data type for this variĆ
able must be the same data type as that for In.
D array
D simple
D element of an array
D integer
D double integer
D timer
(name.TPreset and
name.Elapsed)
D counter
(name.CPreset
and name.Current)