FACTORYTALK VIEW SITE EDITION INSTALLATION GUIDE
72
• • • • •
3. In the Explorer window, expand the name of the restored application, right-click the
RSLinx Enterprise servers name, and then click
Properties
.
4. In the General tab, in the field, Computer hosting the RSLinx Enterprise server,
type the name of the production computer, or click Browse to find and select the
computer, and then click
OK
. Acknowledge the warning if needed by clicking OK.
To change the RSLinx Classic server computer name
1. Open the restored application in the FactoryTalk Administration Console. To learn
how to do this, see the previous task.
2. In the Explorer window, expand the name of the restored application, right-click the
RSLinx Classic servers name, and then click
Properties
.
3. In the General tab, in the field, Computer that will run the OPC server, type the
name of the production computer, or click Browse to find and select the computer, and
then click
OK
.
FTViewSEInstallENU.book Page 72 Wednesday, July 16, 2014 10:53 AM