Chapter 8
Reference
8–11
Parameter 464 – [A>CA Indirect 1]
Parameter 364 – [B>CA Indirect 1]
Use: A fast sink parameter for use by the function blocks
Parameter Type: Fast Sink
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a fast sink used by function blocks to
obtain information from Drive parameters whose source is outside of the
MCA board. This parameter can be linked to any Drive source parameter.
Parameter 465 – [A>CA Indirect 2]
Parameter 365 – [B>CA Indirect 2]
Use: A fast sink parameter for use by the function blocks
Parameter Type: Fast Sink
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a fast sink used by function blocks to
obtain information from Drive parameters whose source is outside of the
MCA board. This parameter can be linked to any Drive source parameter.
Parameter 466 – [A>CA Indirect 3]
Parameter 366 – [B>CA Indirect 3]
Use: A fast sink parameter for use by the function blocks
Parameter Type: Fast Sink
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a fast sink used by function blocks to
obtain information from Drive parameters whose source is outside of the
MCA board. This parameter can be linked to any Drive source parameter.
Parameter 467 – [A>CA Indirect 4]
Parameter 367 – [B>CA Indirect 4]
Use: A fast sink parameter for use by the function blocks
Parameter Type: Fast Sink
Program Terminal Units: None
Minimum Value: –32767
Maximum Value: 32767
Default Value: None
Description: This parameter is a fast sink used by function blocks to
obtain information from Drive parameters whose source is outside of the
MCA board. This parameter can be linked to any Drive source parameter.