Chapter 3
Configuration & Interfacing
3–43
Data Format:
Parameter Value – Drive units, may need to be scaled by the Controller
prior to being used in the Program.
Maximum Value – Drive units, may need to be scaled by the PLC
Controller prior to being used in the Program.
Minimum Value – Drive units, may need to be scaled by the PLC
Controller prior to being used in the Program.
Descriptor – A numeric value used by Allen-Bradley program terminals to
scale parameter data into the appropriate engineering units.
Parameter Text – The parameter text is provided in the following format.
Each parameter text word contains two bytes in ASCII format, which
represent the text displayed by the Drive’s program terminals.
NOTE:Any parameter text that is returned comes back with each byte
reversed.