Rockwell-automation 1738-ADNX ArmorPoint I/O DeviceNet Adapters Manual de usuario Pagina 36

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 134
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 35
Publication 1738-UM001A-EN-P - February 2005
2-20 What Is the ArmorPoint DeviceNet Adapter?
The four data transfers are not necessarily sequential. Transfers 2 and
3 typically occur more frequently than transfers 1 and 4.
Image Table Mapping
Your adapter receives data from:
master devices (e.g., scanners) - output data is then passed to
ArmorPoint I/O modules
input modules - input data is passed to the scanner
The adapter must map the data it receives to its internal memory
before passing it to the appropriate device. The I/O map for a module
is divided into:
read bytes - input and status bytes
write bytes - output and configuration bytes
The data is mapped by 3 buffers for input data (each representing an
I/O connection on the primary DeviceNet) and 1 buffer for output
data (representing data sent for Poll or COS connections on the
primary DeviceNet).
The number of read bytes or write bytes can be 2 or more. The length
of each I/O module's read bytes and write bytes vary in size
depending on module complexity. Each I/O module supports at least
1 input byte or 1 output byte. Status and configuration are optional,
depending on the module.
Vista de pagina 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 133 134

Comentarios a estos manuales

Sin comentarios