Rockwell-automation 1771-CFM Config. Flowmeter Installation Instructio Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1771-CFM Config. Flowmeter Installation Instructio. Rockwell Automation 1771-CFM Config. Flowmeter Installation Instructions User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Publication 1771ĆIN043B-EN-P - July 2002
Configurable
Flowmeter Module
(Catalog Number 1771-CFM)
Use this document as a guide when installing a Configurable
Flowmeter module.
To See page
Important User Information 1
Calculate power requirements 4
Set the module operation jumpers 4
Set the input channel jumpers 5
Determine CFM module placement 6
Key the backplane connector 6
Install the module 7
Make connections to the field wiring arm 8
Ground the module 11
Configure the module 12
Interpret module status and input data 15
For this reference information See page
Diagnostics 16
Status indicators 16
Specifications 18
Because of the variety of uses for the products described in this
publication, those responsible for the application and use of these
products must satisfy themselves that all necessary steps have been
taken to assure that each application and use meets all performance
and safety requirements, including any applicable laws, regulations,
codes and standards. In no event will Rockwell Automation be
responsible or liable for indirect or consequential damage resulting
from the use or application of these products.
Any illustrations, charts, sample programs, and layout examples
shown in this publication are intended solely for purposes of
example. Since there are many variables and requirements associated
with any particular installation, Rockwell Automation does not
assume responsibility or liability (to include intellectual property
liability) for actual use based upon the examples shown in this
publication.
This icon is used when
additional information
is available in the
Configurable Flowmeter
Module User Manual,
publication 1771Ć6.5.99.
Important User Information
Installation Instructions
Contents
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - Flowmeter Module

Publication 1771ĆIN043B-EN-P - July 2002ConfigurableFlowmeter Module(Catalog Number 1771-CFM)Use this document as a guide when installing a Configurab

Pagina 2 - IMPORTANT

Configurable Flowmeter Module10Publication 1771ĆIN043B-EN-P - July 2002Wiring Examples (continued)Standard Output (O0)ExternalPower Supply #15Ć30V dc

Pagina 3

Configurable Flowmeter Module 11Publication 1771ĆIN043B-EN-P - July 2002When using shielded cable wire, ground the foil shield anddrain wire only at

Pagina 4 - Operational Jumper

Configurable Flowmeter Module12Publication 1771ĆIN043B-EN-P - July 2002Configure the ModuleTo configure the CFM module, you enterBTW and BTR instruct

Pagina 5 - Set the Input Channel

Configurable Flowmeter Module 13Publication 1771ĆIN043B-EN-P - July 2002Modes of OperationYou configure the CFM module for these modes of operation:U

Pagina 6 - Placement

Configurable Flowmeter Module14Publication 1771ĆIN043B-EN-P - July 2002BTW Word AssignmentsWord(s)ÀBitÁWord(s)À15 14 13 12 11 10 09 08 07 06 05 04 03

Pagina 7 - Install the Module

Configurable Flowmeter Module 15Publication 1771ĆIN043B-EN-P - July 2002Your PLC processor gets data from the CFM module using BTRinstructions in you

Pagina 8 - Field Wiring Arm

Configurable Flowmeter Module16Publication 1771ĆIN043B-EN-P - July 2002The CFM module returns diagnostics to the PLC processor in wordsone and two of

Pagina 9 - Wiring Examples

Configurable Flowmeter Module 17Publication 1771ĆIN043B-EN-P - July 2002Hazardous LocationsThe following information applies when operating this equi

Pagina 10 - Wiring Examples (continued)

Configurable Flowmeter Module18Publication 1771ĆIN043B-EN-P - July 2002Number of Input Channels4Module Location1771ĆA1B, ĆA2B, A3B, ĆA3B1, ĆA4B (seri

Pagina 11 - Ground the Module

Configurable Flowmeter Module 19Publication 1771ĆIN043B-EN-P - July 2002Environmental ConditionsOperatingTemperatureIEC 60068-2-1 (Test Ad, Operating

Pagina 12 - Configure the Module

Configurable Flowmeter Module2Publication 1771ĆIN043B-EN-P - July 2002Allen–Bradley publication SGI–1.1, Safety Guidelines forApplication, Installati

Pagina 13 - Modes of Operation

Configurable Flowmeter Module20Publication 1771ĆIN043B-EN-P - July 2002European Zone 2 CertificationThis equipment is intended for use in potentially

Pagina 14 - BTW Word Assignments

Configurable Flowmeter Module 3Publication 1771ĆIN043B-EN-P - July 2002ATTENTION!Environment and EnclosureThis equipment is intended for use in a Pol

Pagina 15 - Interpret Module Status

CFM QRDQRC19807 Configurable Flowmeter Module4Publication 1771ĆIN043B-EN-P - July 2002!ATTENTIONPreventing Electrostatic DischargeThis equipment is se

Pagina 16 - Diagnostics and

Configurable Flowmeter Module 5Publication 1771ĆIN043B-EN-P - July 2002Set the Input ChannelJumpersThese jumpers Are used to setflowmeter jumpers flo

Pagina 17 - Hazardous Locations

Configurable Flowmeter Module6Publication 1771ĆIN043B-EN-P - July 2002Place your module in any slot of the I/O chassis except for theextreme left slo

Pagina 18 - Specifications

Configurable Flowmeter Module 7Publication 1771ĆIN043B-EN-P - July 2002Install the ModuleWhen you insert or remove themodule while backplane power is

Pagina 19

Configurable Flowmeter Module8Publication 1771ĆIN043B-EN-P - July 2002The following tables and wiring diagramsrepresent wiring for a flowmeter input

Pagina 20 - User Manuals

Configurable Flowmeter Module 9Publication 1771ĆIN043B-EN-P - July 2002Wiring Examples1357911246810121771ĆWN246810121357911F0 (500mV)F0 InputF0 (TTL)

Comentarios a estos manuales

Sin comentarios