Operating Functions
Chapter 5
5–14
Action taken: You can use the PROG1 command to program the
resident EPROM with baud rate information. When the module is
“powered-up” the module reads this information and initializes the
program port with the stored baud rate. The “sign-on” message is sent to
the console immediately after the module completes its reset
sequence. If the baud rate on the console device is changed you must
program a new EPROM to make the module compatible with the new
console.
If you have already used a PROG2 command, you cannot use the
PROG 1 command.
Action taken: The PROG2 command functions the same as the
PROG1 command except for the following. Instead of “signing-on” and
entering the command mode, the module immediately begins executing
the first program stored in the resident EPROM, if no program is stored
in RAM. Otherwise it executes the RAM program. You can use the
PROG2 command to RUN a program on power-up without connecting to
a console. Saving PROG2 information is the same as typing a ROM 1,
RUN command sequence. This feature also allows you to write a special
initialization sequence in BASIC and generate a custom “sign-on”
message for specific applications.
If you have already used a PROG1 command, you cannot use the
PROG 2 command.
5.3.14
Command: PROG1
5.3.15
Command: PROG2